Technical Reference Note  
Rev.12.08.17_#1.1  
ERM 10W Series  
Page 53  
Output Over Current Protection  
To provide hiccup mode protection in a fault (output overload) condition, the unit is equipped with internal current limiting  
circuitry and can endure overload for an unlimited duration.  
Output Over Voltage Protection  
The output overvoltage clamp consists of control circuitry, which is independent of the primary regulation loop, that  
monitors the voltage on the output terminals.  
The control loop of the clamp has a higher voltage set point than the primary loop. This provides a redundant voltage  
control that reduces the risk of output overvoltage. The OVP level can be found in Table 3.  
Maximum Capacitive Load  
The ERM 10W series has limitation of maximum connected capacitance at the output. The power module may be operated  
in current limiting mode during start-up, affecting the ramp-up and the startup time. The maximum capacitance can be  
found in in Table 3.  
Thermal Considerations  
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and  
board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case  
temperature must be kept below 105. The derating curves are determined from measurements obtained in a test setup.  
.
Position of air velocity  
probe and thermocouple  
Air Flow  
50mm / 2in  
15mm / 0.6in  
DUT  
 复制成功!