欢迎访问ic37.com |
会员登录 免费注册
发布采购

DPF600 参数 Datasheet PDF下载

DPF600图片预览
型号: DPF600
PDF下载: 下载PDF文件 查看货源
内容描述: 双输出600瓦AC / DC PFC前端分布式电源架构 [Dual output 600 Watt AC/DC PFC front-end for distributed power architectures]
分类和应用: 功率因数校正
文件页数/大小: 2 页 / 66 K
品牌: ARTESYN [ ARTESYN TECHNOLOGIES ]
 浏览型号DPF600的Datasheet PDF文件第2页  
DPF600 SERIES
Dual output
600W front end
EN61000-3-2 compliant
Hot pluggable
N+1 redundancy
Full set of status signals
EN55022, EN55011 conducted emissions level B
UL, TÜV, CSA and BABT approvals
Patent No. 5446366
[ 2 YEAR WARRANTY ]
The DPF600 is a 600W universal input AC/DC front end power supply in a fully
enclosed hot pluggable case with built-in fan, front panel with handle, IEC input
connector, on/off switch and DIN output signal connector. Providing dual 49V and 5V
outputs with a full set of status signals, the DPF600 is designed as a slot-in front end
for distributed power systems. The DPF600 provides 600W of output power and is
fully compliant with EN61000-3-2. Standard features include current sharing and full
protection against overvoltage, overload and short circuit. Remote or local system
monitoring is possible via a full set of status signals that include fan fail, DC good,
remote inhibit and current monitoring. The DPF600, with full international safety
approval and the CE mark, meets conducted emissions EN55022 level B. The
DPF600 is designed for use as a front end in medium power communication
applications adopting distributed power architecture. The DPF600 can be used in
conjunction with our complete range of 3 to 200W DC/DC converters to fully configure
a distributed power system.
SPECIFICATION
OUTPUT SPECIFICATIONS
Voltage set point
Total regulation
Rise time
Transient response
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
EMC CHARACTERISTICS
-49VDC ±245mVDC
with 2A load applied
Radiated emissions
Conducted emissions
Harmonic current emm.
Electrical fast
transients/bursts
Surge susceptibility
EN55022/11, FCC part 15
EN55022/11, FCC part 15
EN61000-3-2
EN61000-4-4
EN61000-4-5
Level A
Level B
Compliant
Level 3
Level 3
Main output
Full load to no load
At turn-on
Main output
50% to 100%
step at 1.0A/µs
Main output
Auxiliary output
Latching main output
Latching
±5.0%
0.5s, max.
5.0% max. dev.,
1ms recovery
to 1.0%
750mV pk-pk,
100mV pk-pk
-55V to -60V
5.7V to 6.5V
750W
GENERAL SPECIFICATIONS
Hold-up time
Efficiency
Isolation voltage
Switching frequency
Approvals and
standards
Weight
MTBF
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating ambient
0°C to +50°C
Non-operating
-40°C to +85°C
50°C to 70°C ambient Derate to 50%
Built-in fan
Non-condensing
Operating
Non-operating
5Hz to 500Hz
5% to 85% RH
10,000 feet max.
40,000 feet max.
2.4G rms peak
120VAC, 60Hz FL
20ms @ 600W
82% min.
3000VAC
1500VAC
50kHz
EN60950, UL1950, BABT
CSA C22.2 No. 950
6.9kg (15Ibs)
500,000 hours
demonstrated
Ripple and noise
(0Hz to 30MHz)
Overvoltage protection
Output power limit
Short circuit protection
Current sharing
100Vin, load >66% rated
Input/output
Input/chassis
Non-latching
Auto-recovery
±10%, 3V droop from
15% to 100%
INPUT SPECIFICATIONS
Input voltage range
Input frequency range
Input surge current
Input surge
Safety ground
leakage current
Input current
Input fuse
Power factor
85 to 264VAC
47Hz to 63Hz
230VAC, cold start @ 25°C
300VAC
120VAC, 60Hz
230VAC, 50Hz
90VAC, 600W
220VAC
Non-replaceable
35A max.
20ms
0.2mA
0.4mA
7.35A rms max.
2.84A rms max.
15A
Cooling
Relative humidity
Altitude
Vibration
International Safety Standard Approvals
0.99 120Vin, >66% load
TÜV
VDE0805/EN60950/IEC950
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
PAGE 1
Certificate No. 606090