CXE15 Single Series | 10.8 to 15W DC/DC
High Efficiency DC/DC converters
Note 1
Hot spot temperature is defined as the highest temperature
measured at any one of the specified hotspot checkpoints.
See Figure 46: Hotspot temperature check points.
Note 2
The control pin is referenced to Vin-.
Note 3
The CXE15 is supplied as standard with active high logic.
Control input pulled low: Unit disabled.
Control input left open: Unit enabled.
Figure 46: Hot Spot Location on all Models
Note 4
Thermal reference set up: Unit mounted on an edge card test
board 215mm x 115mm. Test board mounted vertically. For test
details and recommended set-up see Application Note 116.
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is accessible only to trained personnel. The user
must provide the recommended fusing in order to comply with
safety approvals.
23
www.artesyn.com