LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
|
350W AC/DC
350 Watt
AC/DC high wattage power supplies with PFC
FEATURES
Current share
(See Note 12)
Power OK
(See Note 13)
Remote-sense
System inhibit
Power fail detect
(See Note 13)
Forced
Asserted Low
0.4V
Asserted high
Asserted low
Main output and
auxiliary 1 if 5V or 3.3V
Main output >75%
Main output and
auxiliary 1 if 5V or 3.3V
Inhibits all outputs
Indicates loss of AC
4ms warning
15A
Notes
1
2
3
The unit must be powered up into the recommended minimum loads to
ensure the outputs come up.
Combined maximum output power for Aux. 1, 2 and 3 is 220W.
For models -9604 and -9692, on the aux 1 channel, output ripple and
noise is measured 6 inches down the output cables through a 1 foot long
twisted pair terminated with a parallel combination of a 10µF electrolytic
and a 0.1µF ceramic capacitors. For all other channels on all models,
ripple and noise is measured directly at the output terminals.
No shutdown or latch-up occurs; voltage is internally limited to specified
range.
Aux. 2 tracks Aux. 3, Aux. 4 not adjustable.
Aux. 3 tracks Aux. 2.
Output is not adjustable.
CMP350-9604 rated operation:
Graph 1
8A
4
5
6
7
8
1
10A
AC INPUT
10A
Sum of 12V
Channel
Loads*
5A
RATED
OPERATION
OUTPUT
0A
5A
PFD SIGNAL
POWER GOOD SIGNAL
10A
15A
20A
3.3 V Channel Load
t1
t2
* Max. load for AUX2 is 10A
Max load for AUX3 is 5A
t1 Varies with line and load
t2
4ms
t1 + t2
20ms
9
The auxiliary channels must share power as indicated by graph 1.
The maximum output power is 220W.
CMP350-9692 rated operation:
Graph 2
15A
8A
EXTERNAL OUTPUT TRIMMING
Main channel trim connections
12CH1
(14)
10A
Sum of 12V
Channel
Loads*
10A
TRIM
UP/DOWN
TRIMAIN
TRIM
DOWN
GND1
TRIM
UP
RATED
OPERATION
5A
0A
5A
10A
15A
5V Channel Load
* Max. load for AUX2 is 10A
Max load for AUX3 is 5A
Aux. 1 channel trim connections. (-9601, -9602, -9603, 9606)
Aux. 2 channel trim connections (-9604, -9692)
12CH2
TRIM
UP/DOWN
TRIMAUX
TRIM
DOWN
GND2
TRIM
UP
10
11
12
13
The auxiliary channels must share power as indicated by graph 2.
The maximum output power is 220W.
A minimum of 300LFM of forced air cooling is required for proper
operation of the CMP350.
All outputs must be derated linearly from maximum specified loads during
operation above 50
°
C.
Current share is a single wire share circuit that allows the main output on
multiple CMP350 units to be operated in parallel. Auxiliary channels share
on -9604 and -9692 models by connecting the CSAUX channel.
The power fail detect and power OK signals are open-collector outputs
which will sink 40mA or less in the low state and should be pulled up to a
bias voltage with an appropriately sized resistor.
VOL
IOL
VOH
Min.
0V
0A
4V
Max.
0.4V
-40mA
40V
Aux. 1 channel trim connections (-9604, -9692)
AUX1SET
GND3
TRIM
UP/DOWN
TRIMAUX2
TRIMAUX2
The system inhibit and output inhibit signals require a current source to be
asserted high.
Min.
Max.
VIH
3.5V
15.0V
IIH
0mA
-10mA
14 Connection from TRIMAUX2 to AUX1SET causes the output for Ch. aux. 1
on models -9604 and -9692 to regulate at its nominal factory set voltage.
15 3 orthogonal axes, random vibration, 10 minute test per axes.
16 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
TRIMAUX2 is connected to
AUX1SET by a factory fitted
jumper to ensure CH. 1
regulates at the nominal
set voltage
To trim CH1, remove the
jumper and connect a resistor
between GND3
and TRIMAUX2
http://www.artesyn.com
PAGE 65