AVQ100-36S3V3 DC-DC Converter
5/15
Electromagnetic compatibility requirements
Test Item
Regulations
Criteria
Notes & Conditions
EN 55022
Conducted Emission
/
DC input port, Class A Limits
IEC/EN61000-4-2
Immunity to Electrostatic
Discharge
B
B
Enclosure Port, Level 3
IEC/EN61000-4-4
Immunity to Electrical Fast
Transient
DC input port, Level 3
IEC/EN61000-4-5
DC input port
See EMC test conditions
Immunity to Surges
B
Line to Ground(earth): 600V
Line to Line: 600V
IEC/EN61000-4-6
Immunity to Continuous
Conducted Interference
A
B
DC input port, Level 2
Immunity To Voltage Dips and
short interruptions and voltage
variations
EN 61000-4-29
DC input port
Criterion A: Normal performance during and after test.
Criterion B: For EFT and surges, low-voltage protection or reset is not allowed. Temporary output
voltage fluctuation ceases after disturbances ceases, and from which the EUT recovers its normal
performance automatically.
For Dips and ESD, output voltage fluctuation or reset is allowed during the test, but recovers to its
normal performance automatically after the disturbance ceases.
Criterion C: Temporary loss of output, the correction of which requires operator intervention.
Criterion D: Loss of output which is not recoverable, owing to damage to hardware.
http://www.emersonnetworkpower.com.cn