Technical Reference Note
Rev.09.30.14_#1.0
AVO250-48S28B
Page 3
Electrical Specifications
Absolute Maximum Ratings
Stress in excess of those listed in the “Absolute Maximum Ratings” may cause permanent damage to the power supply.
These are stress ratings only and functional operation of the unit is not implied at these or any other conditions above
those given in the operational sections of this TRN. Exposure to any absolute maximum rated condition for extended
periods may adversely affect the power supply’s reliability.
Table 1. Absolute Maximum Ratings:
Parameter
Model
Symbol
Min
Typ
Max
Unit
Input Voltage
Operating -Continuous
Non-operating -100mS
All
All
-
-
-
-
80
100
Vdc
Vdc
VIN,DC
Maximum Output Power
Ambient Operating Temperature
Isolation Voltage1
All
All
PO,max
TA
-
-
-
250
+85
W
-40
OC
Input to outputs
Input to metal
Output to metal
1500
1000
500
-
-
-
-
-
-
Vdc
Vdc
Vdc
All
Operating baseplate temperature2
All
-40
+100
OC
Storage Temperature
All
All
TSTG
-55
-
-
+125
5
OC
Voltage at remote ON/OFF pin
Humidity (non-condensing)
-0.3
Vdc
Operating
Non-operating
All
All
-
-
-
-
95
95
%
%
Note 1 - 1mA for 60s, slew rate of 1500V/10s.
Note 2 - See thermal derating of output power in Table 6.
Artesyn Embedded Technologies