Technical Reference Note
Output Specifications
Rev.10.13.14_#1.1
AVE240C-48S12
Page 6
Table 3. Output Specifications, con’t:
Parameter
Conditions1
Symbol
Min
265
-0.7
3.5
3.5
-0.7
14.6
-
Typ
Max
275
1.2
12
12
1.2
16
-
Unit
KHz
V
Switching frequency
All
All
All
All
All
All
All
All
All
fSW
270
Off-statevoltage
-
Remote ON/OFF
control (positive logic)
On-state voltage
Off-statevoltage
On-state voltage
-
V
-
-
V
Remote ON/OFF
control (Negative logic)
V
Output over-voltageprotection4
Output over-temperatureprotection5
Over-temperaturehysteresis
VO
T
-
V
118
10
-
OC
OC
V
T
-
-
Output voltage remote sense range
VO
-
0.5
Telcordia SR-332-
2006; 80% load,
300LFM, 40 OC TA
MTBF
-
1.5
-
106 h
Note 4 – Hiccup: auto-restart when over-voltage condition is removed.
Note 5 – Auto recovery.
Artesyn Embedded Technologies