Technical R f rence Note
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 60W Series
Page 3
Electrical Specifications
Absolute Maximum Ratings
Stress in excess of those listed in the “Absolute Maximum Ratings” may cause permanent damage to the power supply.
These are stress ratings only and functional operation of the unit is not implied at these or any other conditions above
those given in the operational sections of this TRN. Exposure to any absolute maximum rated condition for extended
periods may adversely affect the power supply’s reliability.
Table 1. Absolute Maximum Ratings:
Parameter
Model
Symbol
Min
Typ
Max
Unit
Input Voltage
AC continuous operation
DC continuous operation
All models
All models
VIN,AC
VIN,DC
88
124
-
-
264
370
Vac
Vdc
Maximum Output Power
Convection continuous operation
All models
PO,max
-
-
60
W
Isolation Voltage
Input to Output
Input to Safety Ground
Output to Earth Ground
All models
All models
All models
-
-
-
-
-
-
4242
2121
500
Vdc
Vdc
Vdc
Ambient Operating Temperature
All models
All models
TA
-20
-40
-
-
+701
+85
OC
OC
Storage Temperature
TSTG
Humidity (non-condensing)
Operating
Non-operating
All models
All models
20
10
-
-
90
95
%
%
MTBF
All models
-
407.1
-
Khours
Note 1 - Derate each output at 2.5% per degree C from 50 OC to 70 OC.
Artesyn Embedded Technologies