VER : A_4
update : 2018.06.06
AC -DC ITE & Medical Power Module
MQC150 SERIES
150 Watts
ELECTRICAL SPECIFICATIONS
All specifications valid at 230VAC input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
Safety
MQC150-12S
MQC150-24S
MQC150-48S
Approval
UL / IEC / EN 60601 3.1rd Edition & UL / IEC / EN 60950 AM2
EN55011 Conducted & Radiated Class B
EN55011 Class I class B / Class II class A
EN60601-1-2 4th edition
(Note 5)
(Note 5)
Conducted EMI
Radiated EMI
EMS
EMC
NOTE
1. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
2. Hold-up Time measured at 90% Vout.
3. Please check the derating curve for more details.
4. After 30 minutes of burn-in
5. Please secure the power supply unit to your metal case by using the four screw holes in the corners for
either Class I or Class II equipment
6. Please refer to our PDF file "AC-DC Application" on our website: www.archcorp.com.tw
DERATING
TRIM
12S
~
24S
~
48S
~
Trim
→
+5%
0%
+5%
0%
+5%
0%
34KΩ
10MΩ
37.4KΩ
10MΩ
38KΩ
10MΩ
-V
Trim
→
-5%
-5%
-5%
0%
0%
0%
10MΩ
~
106KΩ
10MΩ
~
270KΩ
10MΩ
~
640KΩ
+V
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-