Power Line Filters
Single Stage Wire Leads
62-PML Series
Features
I
I
Tested and found to be
IAW VDE 0565 Part 3
I
I
I
I
I
Compact design requires minimal real estate space
Suitable for products that must conform
to FCC and FTZ regulations
Excellent attenuation for high voltage impulse
Metal case provides effective shielding
Excellent filtering characteristics for both normal mode
and common mode
Structure provides effective shielding for noise
generated externally and internally
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF57)
Digital equipment
Personal computers and peripherals
Measuring instruments
Medical equipment
Factory automation equipment
Circuit Diagram
1
L
1
C
X
R
C
X
C
Y
3
Applications
I
I
I
I
I
E
C
Y
2
4
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
1.5A
3A
Leakage Current
(Max.)
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
C
Y
Capacitance
C
X
Inductance
(L
1
)
10.0mH
Temperature
Rise (Max.)
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
0.1uF
250VAC
4.3mH
2.4mH
30°C
5A
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 62-PML-015 Series: 3.06 ounces (87 grams)
62-PML-030 Series: 3.17 ounces (90 grams)
62-PML-050 Series: 3.28 ounces (93 grams)
Discharge time: 0.4 sec. max.
API TECHNOLOGIES
• 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH
• Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF56