Power Line Filters
Single Stage
62-LMF & LMB Series
Features
Tested and found to be
IAW VDE 0565 Part 3
I
Space saving, compact designs
I
Suitable for products that must conform
to FCC and FTZ regulations
Excellent filtering characteristics for both normal mode
and common mode
Circuit Diagram
I
I
Structure provides effective shielding for noise
generated externally and internally
CY
1
I
I
I
3
Metal case provides effective shielding
Rugged construction
Operating temperature: -25°C to +85°C
L1
CX
CX
(including temperature rise, see graph on page PF61)
R
Applications
E
4
CY
I
Digital equipment
Office automation equipment, such as copy
and fax machines
Computers and peripherals
I
I
2
I
Instrumentation and controls
Specifications
Rated Voltage
Rated
Leakage Current
(Max.)
Capacitance
Inductance
(L1)
Temperature
Rise (Max.)
Model*
(@ 50/60Hz)
Current
CY
CX
62-LMB-030-5-11
62-LMF-030-5-11
62-LMB-050-5-11
62-LMF-050-5-11
62-LMB-080-5-11
62-LMF-080-5-11
62-LMB-100-5-11
62-LMF-100-5-11
0.1uF
14mH
3A
5A
0.1uF & .22uF
.22uF
7.0mH
4.2mH
2.2mH
250VAC
0.50mA
3300pF
45°C
8A
10A
.33uF
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Discharge time: 0.4 sec. max.
*62-LMF - designates Fast-on terminals
62-LMB - designates Bolt-in terminals
62-LML - wire lead in/outputs also available
Weight: 5.3 ounces (150 grams)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF60