Power Entry Modules
High Frequency Attenuation
Bolt-in for PCB Applications
60-BHP Series
Tested and found to be
IAW VDE 0565 Part 3
Features
I
Ideally suited for products that must
conform to FCC part 15 regulations
I
Metal cased filter offers high performance
I
Meets over voltage of IEC 664 category II
and complies with IEC 950
Solder lug, Fast-on tab styles available (see page PF20)
Circuit Diagram
I
I
PCB mounting minimizes space and provides
economical installation
I
Excellent filtering characteristics for high frequencies
I
Earth coil standard
3
1
I Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF49)
CY
L1
CX
Applications
E
E
I
Digital equipment
CY
I
Personal computers and peripherals
I
Measuring instruments
2
4
I
Monitor and display units
L2
Specifications
Rated Voltage
Rated
Leakage Current
(Max.)
Capacitance
Inductance
Temperature
Rise (Max.)
Model
(@ 50/60Hz)
Current
CY
CX
(L1)
(L2)
60-BHP-010-3-11
60-BHP-010-3-4
60-BHP-010-5-11
60-BHP-010-5-4
60-BHP-020-3-11
60-BHP-020-3-4
60-BHP-020-5-11
60-BHP-020-5-4
60-BHP-030-3-11
60-BHP-030-3-4
60-BHP-030-5-11
60-BHP-030-5-4
60-BHP-060-3-11
60-BHP-060-3-4
60-BHP-060-5-11
60-BHP-060-5-4
0.1uF 20%
.047uF 20%
0.1uF 20%
.047uF 20%
0.1uF 20%
.047uF 20%
0.1uF 20%
.047uF 20%
0.1uF 20%
.047uF 20%
0.1uF 20%
.047uF 20%
0.1uF 20%
.047uF 20%
0.1uF 20%
.047uF 20%
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
2200pF 20%
1A
2A
3A
6A
6mH
3300pF 20%
2200pF 20%
3300pF 20%
2200pF 20%
3300pF 20%
2200pF 20%
3300pF 20%
2.4mH
1.2mH
0.53mH
30°C
250VAC
18.3 uH
45°C
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF48