Switched and Fused Filtered
Power Entry Modules
For General Purpose Applications
64-65-BSF/64-65-SSF Series
Features
Tested and found to be
IAW VDE 0565 Part 3.
I
North American and Metric fuse
holders available
Fuse holder and double pole power ON/OFF switch
I
Applications
provided in a convenient/compact package
Suitable for products that must conform
to FCC and FTZ requirements
Meets over voltage category II of IEC 664
I Computers and
I Digital equipment
I
peripheral equipment
I Electronic equipment
I
Measuring and testing instruments
I Telecommunications equipment
I
and complies with IEC 950
Metal case provides effective EMI shielding
Easy access fuse drawer with space for spare fuse
Circuit Diagram
I
I
L
L
CY
I
Flange-mounted or snap-in styles available
for quick mounting
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF39)
CX
CX
E
E
N
R
CY
I
N
Specifications
Rated Voltage
Rated
Leakage Current
(Max.)
Capacitance
CX1
Inductance
(L1)
Temperature
Rise (Max.)
Model*
(@ 50/60Hz)
Current
CY
CX2
64-XXX-020-3-12
64-XXX-020-3-04
64-XXX-020-3-14
64-XXX-020-3-06
64-XXX-020-5-12
64-XXX-020-5-04
64-XXX-020-5-14
64-XXX-020-5-06
64-XXX-040-3-12
64-XXX-040-3-04
64-XXX-040-3-14
64-XXX-040-3-06
64-XXX-040-5-12
64-XXX-040-5-04
64-XXX-040-5-14
64-XXX-040-5-06
64-XXX-060-3-12
64-XXX-060-3-04
64-XXX-060-3-14
64-XXX-060-3-06
64-XXX-060-5-12
64-XXX-060-5-04
64-XXX-060-5-14
64-XXX-060-5-06
65-XXX-020-3-12
65-XXX-020-3-04
65-XXX-020-3-14
65-XXX-020-3-06
65-XXX-020-5-12
65-XXX-020-5-04
65-XXX-020-5-14
65-XXX-020-5-06
65-XXX-040-3-12
65-XXX-040-3-04
65-XXX-040-3-14
65-XXX-040-3-06
65-XXX-040-5-12
65-XXX-040-5-04
65-XXX-040-5-14
65-XXX-040-5-06
65-XXX-060-3-12
65-XXX-060-3-04
65-XXX-060-3-14
65-XXX-060-3-06
65-XXX-060-5-12
65-XXX-060-5-04
65-XXX-060-5-14
65-XXX-060-5-06
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
10.5mH
45°C
250VAC
250VAC
250VAC
125VAC
125VAC
125VAC
2A
4A
6A
2A
4A
6A
4.2mH
1.6mH
10.5mH
4.2mH
1.6mH
45°C
45°C
45°C
45°C
45°C
0.47uF
Note: Test Voltage 1500VAC one minute, line to ground
Insulation Resistance: 300 MΩ min. at 500VDC
B(S) = Bolt-in terminals or (Snap-in terminals)
Voltage Drop: 1V max. at rated current
Weight: 130g
Inlet: Compatible with IEC-320
* Substitute BSF or SSF for XXX
BSF - Bolt-in switched and fused
SSF - Snap-in switched and fused
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF38