GENERAL  
CONSIDERATIONS  
PA62  
TYPICAL APPLICATION (CONT.)  
The PA62 can be used in a three amplifier configuration for  
a three phase inverter or motor as shown in Figure 4.  
SAFE OPERATING AREA (SOA)  
TheSOAcurvescombinetheeffectofalllimitsforthispower  
op amp. For a given application, the direction and magnitude  
of the output current should be calculated or measured and  
checked against the SOA curves. This is simple for resistive  
loads but more complex for reactive and EMF generating  
loads. The following guidelines may save extensive analyti-  
cal efforts.  
THERMAL CONSIDERATIONS  
ThePA62DKhasalargeexposedintegratedcopperheatslug  
towhichthemonolithicisdirectlyattached. Thesolderconnec-  
tion of the heatslug to a minimum of 1 square inch foil area of  
the printed circuit board will result in thermal performance of  
25°C/W junction to air rating of the PA62DK. Solder connec-  
tion to an area of 1 to 2 square inches of foil is required for  
minimal power applications  
Where the PA62DK is used in higher power applications,  
it is necessary to use surface mount techniques of heatsink-  
ing. Surface mount techniques include the use of a surface  
mount fan in combination with a surface mount heatsink on  
the backside of the FR4/ PC board with through hole thermal  
vias.Otherhighlythermalconductivesubstrateboardmaterials  
are available for maximum heat sinking.  
The Power Derating graph shown below assumes that the  
power dissipation is equal in each of the amplifiers. Power and  
thermal ratings are based on two separate dual monolithic  
power op amps on one integrated copper heat slug. Amps A  
and B are combined on one monolithic die while amps C and  
D are combined on the other. This multi chip configuration  
provides superior thermal performance by isolating each of  
the dual amplifiers. When loading either of the dual amplifiers  
it is possible to achieve better thermal performance by loading  
any combination of amplifiers (A or B) + (C or D).  
ꢊꢋꢌꢍꢎꢏꢐꢏꢈꢑꢒꢓꢌꢔꢌꢕꢖꢋꢏꢔꢖꢀꢑꢏꢂꢃꢄꢅ  
ꢈꢋꢏꢐꢏꢒꢗꢈꢋꢕꢏꢑꢀꢘꢀꢖꢏꢉꢖꢌꢙꢕꢖꢚ  
ꢂꢃꢄꢅ  
ꢆꢇꢈꢉ  
FIGURE 4. 3 Phase Inverter  
GENERAL  
PleasereadApplicationNote1"GeneralOperatingConsider-  
ations"whichcoversstability, supplies, heatsinking, mounting,  
SOAinterpretation, andspecificationinterpretation. Visitwww.  
apexmicrotech.com for design tools that help automate tasks  
such as calculations for stability, internal power dissipation,  
heatsink selection; Apex's complete Application Notes library;  
Technical Seminar Workbook; and Evaluation Kits.  
STABILITY CONSIDERATIONS  
All monolithic power op amps use output stage topologies  
that present special stability problems. This is primarily due to  
non-complementary(bothdevicesareNPN)outputstageswith  
a mismatch in gain and phase response for different polarities  
of output current. It is difficult for the op amp manufacturer to  
optimize compensation for all operating conditions.  
�ꢀꢁꢂꢃꢄꢅꢂꢃꢆꢇꢈꢉꢊ  
ꢖꢔ  
ꢙꢔ  
ꢚꢔ  
ꢕꢔ  
ꢘꢔ  
�ꢀꢁ  
ꢘꢟ  
ꢇꢔꢐꢄꢅꢄꢛꢄꢙꢜꢝꢔ  
ꢗꢄꢍꢕꢁꢂꢈꢉꢈꢊꢋ�ꢄꢂꢆꢍꢇꢊꢇ  
ꢚꢄꢍꢕꢁꢂꢈꢉꢈꢊꢋ�ꢄꢂꢆꢍꢇꢊꢇ  
ꢙꢄꢍꢕꢁꢂꢈꢉꢈꢊꢋ�ꢄꢂꢆꢍꢇꢊꢇ  
ꢘꢕꢖ  
ꢕꢖ  
�ꢀꢁꢂꢃꢄꢅꢁꢆꢃꢇꢈꢉꢇꢊꢋꢃꢀꢊꢇꢌꢆꢃꢆꢍꢎꢂꢏ  
ꢖꢔ  
ꢗꢖ  
ꢘꢔꢔ  
ꢘꢄꢍꢕꢁꢂꢈꢉꢈꢊꢋ�ꢄꢂꢆꢍꢇꢊꢇ  
MOUNTING PRECAUTIONS  
1. Always use a heat sink. Even unloaded the PA62DK can  
dissipate up to .8 watts.  
ꢇꢔꢐꢄꢅꢄꢛꢄꢞꢜꢝꢔ  
2. Avoid bending the leads. Such action can lead to internal  
damage.  
ꢟꢠꢘ  
ꢘꢟ  
ꢜꢟ  
�ꢀꢁꢁꢂꢃꢄꢅꢆꢄꢆꢀꢅꢁꢀꢅꢄꢇꢈꢉꢉꢊꢋꢊꢌꢅꢈꢍꢂꢄꢎꢆꢂꢅꢍꢏꢊꢐꢄꢎꢄꢑꢄꢎꢄꢒꢎꢓ  
This data sheet has been carefully checked and is believed to be reliable, however, no responsibility is assumed for possible inaccuracies or omissions. All specifications are subject to change without notice.  
4
PA62U REV C OCTOBER 2005  
© 2005 Apex Microtechnology Corp.