APA2069
Absolute Maximum Ratings
(Over operatingfree-air temperature range unlessotherwise noted.)
Symbol
Parameter
Supply Voltage Range
Rating
Unit
VDD
-0.3 to 6
V
Input Voltage Range, SE/BTL,
SHUTDOWN
VIN
-0.3 to VDD+0.3
V
TA
TJ
Operating Ambient Temperature Range
-40 to 85
Intermal Limited*1
-65 to +150
260
°
°
°
°
C
C
C
C
Maximum Junction Temperature
Storage Temperature Range
TSTG
TS
Soldering Temperature,10 seconds
-3000 to 3000*2
VESD
PD
Electrostatic Discharge
Power Dissipation
V
-200 to 200*3
Intermal Limited
Notes:
1.APA2069 integrated internal thermal shutdown protection when junction temperature ramp up to 150°C
2.Human body model: C=100pF, R=1500W, 3 positives pulse plus 3 negative pulses
3.Machine model: C=200pF, L=0.5mF, 3 positive pulses plus 3 negative pulses
Recommended Operating Conditions
Min.
Max.
Unit
Supply Voltage, VDD
4.5
2
5.5
V
SHUTDOWN
SE/BTL
High level threshold voltage, VIH
V
4
1.0
3
SHUTDOWN
SE/BTL
Low level threshold voltage, VIL
V
V
Common mode input voltage, VICM
VDD-1.0
Thermal Characteristics
Symbol
Parameter
Value
Unit
RTHJA
Thermal Resistance from Junction to Ambient in Free Air
DIP-16
45
°
C/W
Copyright ã ANPEC Electronics Corp.
3
www.anpec.com.tw
Rev. A.1 - Aug., 2005