Model XC0900A-20
Rev F
Mounting
Coupler Mounting Process
In order for Xinger surface mount couplers to work
optimally, there must be 50Ω transmission lines leading The process for assembling this component is a
to and from all of the RF ports. Also, there must be a conventional surface mount process as shown in Figure
very good ground plane underneath the part to ensure 1. This process is conducive to both low and high volume
proper electrical performance. If either of these two usage.
conditions is not satisfied, insertion loss, coupling, VSWR
and isolation may not meet published specifications.
Overall ground is improved if a dense population of
plated through holes connect the top and bottom ground
layers of the PCB. This minimizes ground inductance
and improves ground continuity. All of the Xinger hybrid
Figure 1: Surface Mounting Process Steps
and directional couplers are constructed from ceramic
Storage of Components: The Xinger II products are
filled PTFE composites which possess excellent electrical
available in either an immersion tin or tin-lead finish.
and mechanical stability having X and Y thermal
Commonly used storage procedures used to control
coefficient of expansion (CTE) of 17-25 ppm/oC.
oxidation should be followed for these surface mount
components. The storage temperatures should be held
between 15OC and 60OC.
When a surface mount hybrid coupler is mounted to a
printed circuit board, the primary concerns are; ensuring
the RF pads of the device are in contact with the circuit
Substrate: Depending upon the particular component,
trace of the PCB and insuring the ground plane of neither
the circuit material has an x and y coefficient of thermal
the component nor the PCB is in contact with the RF
expansion of between 17 and 25 ppm/°C. This coefficient
minimizes solder joint stresses due to similar expansion
signal.
rates of most commonly used board substrates such as
RF35, RO4350, FR4, polyimide and G-10 materials.
Mounting Footprint
Mounting to “hard” substrates (alumina etc.) is possible
To ensure proper electrical and thermal performance
depending upon operational temperature requirements.
The solder surfaces of the coupler are all copper plated
there must be a ground plane with 100%
solder connection underneath the part
with either an immersion tin or tin-lead exterior finish.
Solder Paste: All conventional solder paste formulations
will work well with Anaren’s Xinger II surface mount
components. Solder paste can be applied with stencils or
syringe dispensers. An example of a stenciled solder
paste deposit is shown in Figure 2. As shown in the
figure solder paste is applied to the four RF pads and the
entire ground plane underneath the body of the part.
.430
[10.92]
Multiple
plated thru holes
to ground
4X .040
[1.02]
.220
[5.59]
4X .066 SQ
Ω
4X 50
[1.65]
Transmission
Line
Dimensions are in Inches [Millimeters]
XC0900A-20* Mounting Footprint
USA/Canada:
Toll Free:
(315) 432-8909
(800) 411-6596
+44 2392-232392
Available on Tape
and Reel for Pick and
Place Manufacturing.
Europe: