 浏览型号AAT3200IQY-2.4-T1的Datasheet PDF文件第8页浏览型号AAT3200IQY-2.4-T1的Datasheet PDF文件第9页浏览型号AAT3200IQY-2.4-T1的Datasheet PDF文件第10页浏览型号AAT3200IQY-2.4-T1的Datasheet PDF文件第11页浏览型号AAT3200IQY-2.4-T1的Datasheet PDF文件第13页浏览型号AAT3200IQY-2.4-T1的Datasheet PDF文件第14页浏览型号AAT3200IQY-2.4-T1的Datasheet PDF文件第15页浏览型号AAT3200IQY-2.4-T1的Datasheet PDF文件第16页  
AAT3200  
OmniPower™ LDO Linear Regulator  
Higher input-to-output voltage differentials can be  
obtained with the AAT3200, while maintaining  
device functions in the thermal safe operating area.  
To accomplish this, the device thermal resistance  
must be reduced by increasing the heat sink area  
or by operating the LDO regulator in a duty-cycled  
mode.  
Device Duty Cycle vs. VDROP  
(VOUT = 2.5V @ 25°C)  
3.5  
3
2.5  
200mA  
2
For example, an application requires VIN = 5.0V  
while VOUT = 3.0V at a 150mA load and TA = 85°C.  
VIN is greater than 4.33V, which is the maximum  
safe continuous input level for VOUT = 3.0V at  
150mA for TA = 85°C. To maintain this high input  
voltage and output current level, the LDO regulator  
must be operated in a duty-cycled mode. Refer to  
the following calculation for duty-cycle operation:  
1.5  
150mA  
1
0.5  
0
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Duty Cycle (%)  
PD(MAX) is assumed to be 200mW  
Device Duty Cycle vs. VDROP  
(VOUT = 2.5V @ 50°C)  
IGND = 20µA  
IOUT = 150mA  
VIN = 5.0V  
VOUT = 3.0V  
3.5  
3
100mA  
2.5  
2
200mA  
150mA  
PD(MAX)  
(VIN - VOUT)IOUT + (VIN × IGND  
1.5  
1
%DC = 100  
)
0.5  
0
200mW  
(5.0V - 3.0V)150mA + (5.0V × 20µA)  
%DC = 100  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
%DC = 66.6%  
Duty Cycle (%)  
For a 150mA output current and a 2.0 volt drop  
across the AAT3200 at an ambient temperature of  
85°C, the maximum on-time duty cycle for the  
device would be 66.6%.  
Device Duty Cycle vs. VDROP  
(VOUT = 2.5V @ 85°C)  
The following family of curves shows the safe oper-  
ating area for duty-cycled operation from ambient  
room temperature to the maximum operating level.  
3.5  
3
100mA  
50mA  
2.5  
2
200mA  
150mA  
1.5  
1
0.5  
0
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Duty Cycle (%)  
12  