欢迎访问ic37.com |
会员登录 免费注册
发布采购

AAT3175IWP-T1 参数 Datasheet PDF下载

AAT3175IWP-T1图片预览
型号: AAT3175IWP-T1
PDF下载: 下载PDF文件 查看货源
内容描述: 高效率1X / 1.5X / 2X电荷泵白光LED闪光灯的应用 [High Efficiency 1X/1.5X/2X Charge Pump For White LED Flash Applications]
分类和应用: 闪光灯
文件页数/大小: 12 页 / 247 K
品牌: ANALOGICTECH [ ADVANCED ANALOGIC TECHNOLOGIES ]
 浏览型号AAT3175IWP-T1的Datasheet PDF文件第1页浏览型号AAT3175IWP-T1的Datasheet PDF文件第2页浏览型号AAT3175IWP-T1的Datasheet PDF文件第3页浏览型号AAT3175IWP-T1的Datasheet PDF文件第5页浏览型号AAT3175IWP-T1的Datasheet PDF文件第6页浏览型号AAT3175IWP-T1的Datasheet PDF文件第7页浏览型号AAT3175IWP-T1的Datasheet PDF文件第8页浏览型号AAT3175IWP-T1的Datasheet PDF文件第9页  
AAT3175
High Efficiency 1X/1.5X/2X Charge Pump
For White LED Flash Applications
Electrical Characteristics
1
C
IN
= C
OUT
= C
1
= C
2
= 1.0µF; T
A
= -40°C to +85°C, unless otherwise noted. Typical values are T
A
= 25°C,
V
IN
= 3.5V.
Symbol
Description
Conditions
Min
2.7
1X Mode, 3.0
V
IN
5.5,
Active, No Load Current
1.5X Mode, 3.0
V
IN
5.5,
Active, No Load Current
2X Mode, 3.0
V
IN
5.5,
Active, No Load Current
EN/SET = 0
D1, D4 Max Setting
D2, D3 Max Setting
V
F
:D1:D4 = 3.6V, D2 and D3
in Parallel
0.3
1.0
2.0
Typ
Max
5.5
1.0
3.0
3.7
1.0
110
55
5.0
Units
V
Input Power Supply
V
IN
Operation Range
I
CC
Operating Current
mA
I
SHDN
I
DX
I
(D-Match)
V
TH
Shutdown Current
I
SINK
Average Current Accuracy
Current Matching
2
µA
mA
%
mV
90
45
100
50
0.5
250
1X to 1.5X or 1.5X to 2X Transition
Threshold at Any I
SINK
Pin
Charge Pump Section
T
SS
Soft-Start Time
F
CLK
Clock Frequency
EN/SET
V
EN(L)
Enable Threshold Low
V
EN(H)
Enable Threshold High
T
EN/SET LO
EN/SET Low Time
T
EN/SET HI MIN
Minimum EN/SET High Time
T
EN/SET HI MAX
Maximum EN/SET High Time
T
OFF
EN/SET Off Timeout
T
LAT
EN/SET Latch Timeout
I
EN/SET
EN/SET Input Leakage
100
1000
V
IN
= 2.7V
V
IN
= 5.5V
0.4
1.4
0.3
50
75
500
500
1
75
µs
kHz
V
V
µs
ns
µs
µs
µs
µA
-1
1. The AAT3175 is guaranteed to meet performance specifications over the -40°C to +85°C operating temperature range and is assured
by design, characterization, and correlation with statistical process controls.
2. Current matching is defined as the deviation of any sink current from the average of all active channels.
4
3175.2006.01.1.2