欢迎访问ic37.com |
会员登录 免费注册
发布采购

AAT3151B 参数 Datasheet PDF下载

AAT3151B图片预览
型号: AAT3151B
PDF下载: 下载PDF文件 查看货源
内容描述: 高效率1X / 1.5X电荷泵为白光LED应用 [High Efficiency 1X/1.5X Charge Pump For White LED Applications]
分类和应用:
文件页数/大小: 15 页 / 266 K
品牌: ANALOGICTECH [ ADVANCED ANALOGIC TECHNOLOGIES ]
 浏览型号AAT3151B的Datasheet PDF文件第1页浏览型号AAT3151B的Datasheet PDF文件第2页浏览型号AAT3151B的Datasheet PDF文件第3页浏览型号AAT3151B的Datasheet PDF文件第5页浏览型号AAT3151B的Datasheet PDF文件第6页浏览型号AAT3151B的Datasheet PDF文件第7页浏览型号AAT3151B的Datasheet PDF文件第8页浏览型号AAT3151B的Datasheet PDF文件第9页  
AAT3151B  
High Efficiency 1X/1.5X Charge Pump  
For White LED Applications  
1
Electrical Characteristics  
CIN = COUT = C1 = C2 = 1.0µF; TA = -40°C to +85°C, unless otherwise noted.  
Typical values are TA = 25°C, VIN = 3.5V.  
Symbol  
Description  
Conditions  
Min Typ Max Units  
Input Power Supply  
VIN Operation Range  
2.7  
5.5  
1
V
1X Mode, 3.0 VIN 5.5, Active,  
No Load Current  
1.5X Mode, 3.0 VIN 5.5, Active,  
No Load Current  
0.3  
1
ICC  
Operating Current  
3
mA  
50µA Setting, 1X Mode  
EN/SET = 0  
ISET = 30mA, TA = 25°C  
50  
µA  
µA  
mA  
ISHDN  
IDX  
Shutdown Current  
ISINK Current Accuracy  
1
33  
2
27  
30  
Current Matching Between Any  
Two Current Sink Inputs  
1X to 1.5X Transition Threshold at  
Any ISINK Pin  
I(D-Match)  
VTH  
VF:D1:D4 = 3.6V  
ISET = 20mA  
0.5  
%
3, 4  
150  
mV  
Charge Pump Section  
TSS  
FCLK  
Soft-Start Time  
Clock Frequency  
100  
1000  
µs  
kHz  
EN/SET  
VIL  
VIH  
TEN/SET LO  
Enable Threshold Low  
Enable Threshold High  
EN/SET Low Time  
VIN = 2.7V  
VIN = 5.5V  
0.4  
75  
V
V
1.4  
0.3  
µs  
ns  
µs  
µs  
µs  
µA  
TEN/SET HI MIN Minimum EN/SET High Time  
50  
_
_
TEN/SET HI MAX Maximum EN/SET High Time  
75  
500  
500  
1
_
_
5
TOFF  
TLAT  
IEN/SET  
EN/SET Off Timeout  
EN/SET Latch Timeout  
EN/SET Input Leakage  
6
-1  
1. The AAT3151B is guaranteed to meet performance specifications over the -40°C to +85°C operating temperature range and is  
assured by design, characterization, and correlation with statistical process controls.  
2. Determined by the average of all active channels.  
3. Current matching is defined as the deviation of any sink current at IOUT = 20mA and 2mA.  
4. Specification applies only to the tri-mode charge pump.  
5. The EN/SET pin must remain logic low (less than VIL) for the duration of longer than 500µs to guarantee the off timeout.  
6. The EN/SET pin must remain logic high (greater than VIH) for the duration of longer than 500µs to guarantee the latch timeout.  
4
3151B.2007.09.1.0  
 复制成功!