 浏览型号AAT2801IXN-4.5-T1的Datasheet PDF文件第11页浏览型号AAT2801IXN-4.5-T1的Datasheet PDF文件第12页浏览型号AAT2801IXN-4.5-T1的Datasheet PDF文件第13页浏览型号AAT2801IXN-4.5-T1的Datasheet PDF文件第14页浏览型号AAT2801IXN-4.5-T1的Datasheet PDF文件第16页浏览型号AAT2801IXN-4.5-T1的Datasheet PDF文件第17页浏览型号AAT2801IXN-4.5-T1的Datasheet PDF文件第18页浏览型号AAT2801IXN-4.5-T1的Datasheet PDF文件第19页  
AAT2801  
Multi-Mode Charge Pump for  
White LED Backlight and Flash Applications  
Constant Current Source Output  
Nominal Programming Levels (mA)  
S2Cwire Serial Interface  
The current source output magnitude is controlled  
by the EN/SET pin, using AnalogicTech's S2Cwire  
interface. The interface records rising edges of  
the EN/SET pin and decodes them into 32 indi-  
vidual current level settings each 1dB apart with  
Code 1 reserved for no current. Once EN/SET  
IOUT (typ)  
(mA)  
IOUT (typ)  
(mA)  
Code  
Code  
1
2
0.0  
0.1  
0.2  
0.4  
0.5  
0.7  
1.1  
1.8  
2.0  
2.2  
2.5  
2.8  
3.2  
3.5  
4.0  
4.5  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
5.1  
5.6  
3
6.4  
has been held in the logic high state for time TLAT  
,
the programmed current is seen at the current  
source outputs, and the internal data register is  
reset to 0. For subsequent current level pro-  
gramming, the number of rising edges correspon-  
ding to the desired code must be entered on the  
EN/SET pin.  
4
7.2  
5
8.1  
6
9.2  
7
10.2  
11.5  
13.1  
14.7  
16.6  
18.6  
20.9  
23.6  
26.6  
30.0  
8
9
When EN/SET is held low for an amount of time  
greater than TOFF, the AAT2801 enters into shut-  
down mode and draws less than 1µA from VIN.  
The internal data register is reset to 0 during shut-  
down.  
10  
11  
12  
13  
14  
15  
16  
S2Cwire Serial Interface Timing Diagram  
T
HI  
T
OFF  
T
LO  
TLAT  
EN/SET  
1
2
n-1  
n <= 32  
Data Reg  
0
n
0
charge pump when it is not necessary. To prevent  
this effect, simply connect unused constant current  
source outputs to ground.  
Termination of Unused Current Source  
Outputs  
If any outputs (D1 to D4) are not used, they should  
be terminated by connecting the respective unused  
output directly to ground. This is required to assure  
correct charge pump mode operation. If a given  
unused output is not terminated to ground, it will  
appear to the respective output’s feedback control  
as an infinite impedance load and the unused con-  
stant current source will be set to maximum volt-  
age. Although no current flows from the unused  
current source, the voltage sensed at that node  
could force the charge pump control to activate the  
LED Selection  
The AAT2801 is specifically intended for driving  
white LEDs. However, the device design will allow  
the AAT2801 to drive most types of LEDs with for-  
ward voltage specifications ranging from 2.0V to  
4.3V. Since the D1 to D4 output current sources  
are matched with negligible voltage dependence,  
the LED brightness will be matched regardless of  
the specific LED forward voltage (VF) levels.  
2801.2006.04.1.3  