Advanced Analog Technology, Inc.
ELETRICAL CHARACTERISTICS, VDD = 6.0V (UNLESS OTHERWISE
SPECIFIED) (SEE NOTE 1) (CONT.)
DEAD-TIME CONTROL & PWM
PARAMETER
Input Bias Current
TEST CONDITION
VDTC = 2V
MIN TYP MAX UNIT
IIB
-
0.1
1.0
µA
Vd0 Duty = 0%,fOSC = 10kHz
1.79 1.97 2.15
1.32 1.48 1.64
Input Threshold Voltage
(DTC)
V
Vd100 Duty = 100%,fOSC = 10kHz
VDTC
IDTC
Latch Input Voltage
IDT = 40µA
2.28 2.48
-
-
V
Latch Mode Source Current
DTC1, DTC2=0V
− 560 − 200
µA
OUTPUT STAGE
PARAMETER
TEST CONDITION
MIN TYP MAX UNIT
IO = 75mA(CH1, CH2)
VSAT
Saturation Voltage
-
-
0.8
-
1.2
5
V
ILEAK VO =14.0V
µA
Leakage Current
OPERATING CURRENT
PARAMETER
TEST CONDITION
Output “OFF” State
IDD−ON ROSC = 10kΩ
MIN TYP MAX UNIT
IDD−OFF
-
1.3
1.8
mA
Supply Current
-
1.6
2.4
mA
– 台灣類比科技股份有限公司 –
– Advanced Analog Technology, Inc. –
Page 6 of 16
V1.0