 浏览型号AAT1271AIWO-T1的Datasheet PDF文件第9页浏览型号AAT1271AIWO-T1的Datasheet PDF文件第10页浏览型号AAT1271AIWO-T1的Datasheet PDF文件第11页浏览型号AAT1271AIWO-T1的Datasheet PDF文件第12页浏览型号AAT1271AIWO-T1的Datasheet PDF文件第14页浏览型号AAT1271AIWO-T1的Datasheet PDF文件第15页浏览型号AAT1271AIWO-T1的Datasheet PDF文件第16页浏览型号AAT1271AIWO-T1的Datasheet PDF文件第17页  
PROPRIETARY INFORMATION PRODUCT DATASHEET  
AAT1271A  
TM  
SwitchReg  
1.5A Step-Up Current Regulator for Flash LEDs  
Flash/Safety Timer – Address 1  
Data  
Ratio of MM Timeout  
1*  
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
16/16  
15/16  
14/16  
13/16  
12/16  
11/16  
10/16  
9/16  
8/16  
7/16  
6/16  
5/16  
A timer function that enables the flash current sinks for  
a programmed amount of time is incorporated in the  
AAT1271A. The on-time is programmed by loading the  
Timing Register at Address 1 with a value from 1 to 16  
and by choosing a value for the external timing capaci-  
tor, CT (see Table 3). When data is latched into Address  
1, the data will be used at the next occurrence of an  
asserted FLEN, it will then revert back to the default  
value of Data 1, or 16/16. This feature eliminates the  
need for an external, housekeeping baseband controller  
to contain a safety delay routine. It also serves as a  
protection feature to minimize thermal issues with the  
Flash LEDs in the event an external controller’s flash  
software routine experience hang-up or freeze. If no  
write instruction is applied to Address 1, then the safety  
timer will default to the maximum delay programmed  
externally at CT.  
4/16  
3/16  
2/16  
1/16  
Table 3: Address 1, Flash Safety Timer  
Programming; Maximum Value  
Programmed by CT.  
The Flash Time T can be calculated by the following  
equation:  
T = 7.98s/μF · CT (μF)  
Output Enable Control – Address 2  
Where T is in seconds and CT is in μF.  
In the case where two LEDs are used, each output can  
be enabled or disabled independently in movie mode as  
shown in Table 4. To enable or disable either or both  
FLOUTA and FLOUTB, a write instruction to Address 2 is  
applied to the AAT1271A’s EN/SET pin. If no write  
instruction is applied, the default value for Address 2 is  
FLOUTA, FLOUTB = ON. During a flash event, both  
FLOUTA and FLOUTB will be enabled regardless of the  
movie-mode setting.  
For example, using a 47nF capacitor at CT sets the flash  
timeout to:  
Flash Timeout = 7.98s/μF · 47nF = 375ms  
The relationship between the flash safety timeout and  
the capacitance of the timer capacitor is illustrated in  
Figure 2.  
1200  
1000  
800  
600  
400  
200  
0
Selection  
Data  
FLOUTA  
FLOUTB  
1
2
3
OFF  
OFF**  
ON  
OFF  
ON  
OFF**  
ON  
4*  
ON  
Table 4: Address 2, Movie Mode  
Output Configuration.  
0
20  
40  
60  
80  
100  
120  
140  
CT Capacitor (nF)  
Figure 2: Flash Safety Timeout  
vs. Timer Capacitor.  
*Denotes the default value.  
**A small current will flow due to the start-up test current.  
w w w . a n a l o g i c t e c h . c o m  
1271A.2008.07.1.0  
13