PRODUCT DATASHEET
AAT1141
SwitchRegTM
FastTransient 600mA Step-Down Converter
SW
U1
AAT1141
L1
4.7μH
1
2
3
5
IN
LX
VIN
VOUT
C1
4.7μF
C3
100pF
C2
10μF
R1
442k
GND
EN
1
2
3
Enable
4
R2
221k
OUT
Figure 1: Enhanced Transient Response Schematic.
Control Loop
Current Limit and
Over-Temperature Protection
The AAT1141 is a peak current mode step-down con-
verter. The current through the P-channel MOSFET (high
side) is sensed for current loop control, as well as short
circuit and overload protection. A fixed slope compensa-
tion signal is added to the sensed current to maintain
stability for duty cycles greater than 50%. The peak cur-
rent mode loop appears as a voltage-programmed cur-
rent source in parallel with the output capacitor.
For overload conditions, the peak input current is limit-
ed. To minimize power dissipation and stresses under
current limit and short-circuit conditions, switching is
terminated after entering current limit for a series of
pulses. Switching is terminated for seven consecutive
clock cycles after a current limit has been sensed for a
series of four consecutive clock cycles.
The output of the voltage error amplifier programs the
current mode loop for the necessary peak switch current
to force a constant output voltage for all load and line
conditions. Internal loop compensation terminates the
transconductance voltage error amplifier output. For
fixed voltage versions, the error amplifier reference volt-
age is internally set to program the converter output
voltage. For the adjustable output, the error amplifier
reference is fixed at 0.6V.
Thermal protection completely disables switching when
internal dissipation becomes excessive. The junction
over-temperature threshold is 140°C with 15°C of hys-
teresis. Once an over-temperature or over-current fault
condition is removed, the output voltage automatically
recovers.
Under-Voltage Lockout
Internal bias of all circuits is controlled via the IN input.
Under-voltage lockout (UVLO) guarantees sufficient VIN
bias and proper operation of all internal circuitry prior to
activation.
Soft Start / Enable
Soft start limits the current surge seen at the input and
eliminates output voltage overshoot. When pulled low,
the enable input forces the AAT1141 into a low-power,
non-switching state. The total input current during shut-
down is less than 1μA.
w w w . a n a l o g i c t e c h . c o m
10
1141.2007.12.1.3