欢迎访问ic37.com |
会员登录 免费注册
发布采购

AWU6601RM45Q7 参数 Datasheet PDF下载

AWU6601RM45Q7图片预览
型号: AWU6601RM45Q7
PDF下载: 下载PDF文件 查看货源
内容描述: HELP3TM带1 / WCDMA / TD - SCDMA 3.4 V / 28.25 dBm的线性PA模块 [HELP3TM Band 1 / WCDMA / TD-SCDMA 3.4 V / 28.25 dBm Linear PA Module]
分类和应用: 射频微波
文件页数/大小: 14 页 / 604 K
品牌: ANADIGICS [ ANADIGICS, INC ]
 浏览型号AWU6601RM45Q7的Datasheet PDF文件第1页浏览型号AWU6601RM45Q7的Datasheet PDF文件第2页浏览型号AWU6601RM45Q7的Datasheet PDF文件第4页浏览型号AWU6601RM45Q7的Datasheet PDF文件第5页浏览型号AWU6601RM45Q7的Datasheet PDF文件第6页浏览型号AWU6601RM45Q7的Datasheet PDF文件第7页浏览型号AWU6601RM45Q7的Datasheet PDF文件第8页浏览型号AWU6601RM45Q7的Datasheet PDF文件第9页  
AWU6601  
ELECTRICAL CHARACTERISTICS  
Table 2: Absolute Minimum and Maximum Ratings  
PARAMETER  
MIN  
0
MAX  
+5  
UNIT  
V
SupplyꢀVoltageꢀ(VCC  
)
BatteryꢀVoltageꢀ(VBATT  
ControlꢀVoltagesꢀ(VMODE1, VENABLE  
)
0
+6  
V
)
0
+3.5  
+10  
+150  
V
RFꢀInputꢀPowerꢀ(PIN  
)
-
dBm  
°C  
StorageꢀTemperatureꢀ(TSTG  
)
-40  
Stresses in excess of the absolute ratings may cause permanent damage.  
Functional operation is not implied under these conditions. Exposure  
to absolute ratings for extended periods of time may adversely affect  
reliability.  
Table 3: Operating Ranges  
PARAMETER  
MIN  
TYP  
MAX  
UNIT  
COMMENTS  
UMTS Band 1  
TD-SCDMA Band  
TD-SCDMA Band  
1920  
1880  
2010  
-
-
-
1980  
1920  
2025  
OperatingꢀFrequencyꢀ(f)  
MHz  
SupplyꢀVoltageꢀ(VCC  
)
+3.2  
+3.4  
+4.2  
V
V
POUT < +28.25 dBm  
+2.15  
0
+2.4  
0
+3.1  
+0.5  
PA "on"  
PA "shut down"  
EnableꢀVoltageꢀ(VENABLE  
)
+2.15  
0
+2.4  
0
+3.1  
+0.5  
Low Bias Mode  
High Bias Mode  
ModeꢀControlꢀVoltageꢀ(VMODE1  
RFꢀOutputꢀPowerꢀ(POUT  
ꢀꢀꢀꢀꢀR99ꢀWCDMA,ꢀHPM  
ꢀꢀꢀꢀꢀHSPAꢀ(MPR=0),ꢀHPM  
ꢀꢀꢀꢀꢀR99ꢀWCDMA,ꢀLPM  
ꢀꢀꢀꢀꢀHSPAꢀ(MPR=0),ꢀLPM  
)
V
)
27.75(1) 28.25 28.25  
26.75(1) 27.25 27.25  
3GPP TS 34.121-1, Rel 8  
Table C.11.1.3, Subtest 1  
dBm  
16.5(1)  
15.5(1)  
17  
16  
17  
16  
RFꢀOutputꢀPowerꢀ(POUT),ꢀTD-SCDMA  
ꢀꢀꢀꢀTD-SCDMAꢀ(HPM)  
ꢀꢀꢀꢀTD-SCDMAꢀ(LPM)  
26.5  
15.5  
27  
16.0  
27  
16.0  
3GPP TS 25.62  
Section 6.2.1  
dBm  
°C  
CaseꢀTemperatureꢀ(T  
C
)
-30  
-
+90  
The device may be operated safely over these conditions; however, parametric performance is guaranteed only  
over the conditions defined in the electrical specifications.  
Notes:  
(1) For operation at Vc c = +3.2 V, Po u t is derated by 0.5 dB.  
Data Sheet - Rev 2.0  
10/2009  
3