Table 4: Electrical Specifications - WCDMA Operation (R99 waveform) (Band 1)  
(TC = +25 °C, VCC = +3.4 V, VEN = +1.8 V, 50 Ω system)  
COMMENTS  
PARAMETER  
MIN  
TYP  
MAX  
UNIT  
POUT  
VMODE  
24  
13  
27  
15.5  
30  
19  
+28.2 dBm  
+17 dBm  
0 V  
1.8 V  
Gain  
dB  
dBc  
dBc  
%
-
-
-40  
-44  
-36  
-36  
+28.2 dBm  
+17 dBm  
0 V  
1.8 V  
ACLR1 at 5 Mhz offset (1)  
ACLR2 at 10 Mhz offset (1)  
Efficiency (1)  
-
-
-53  
-56  
-47  
-47  
+28.2 dBm  
+17 dBm  
0 V  
1.8 V  
37  
-
44  
41  
-
-
+28.2 dBm  
+17 dBm  
0 V  
1.8 V  
Quiescent Current (Icq)  
Low Bias Mode  
-
6
-
mA  
tꢂrougꢂ VCC pin 1.8 V  
Mode Control Current  
Enable Current  
-
-
-
0.1  
0.25  
0.1  
mA  
mA  
mA  
tꢂrougꢂ VMODE pins, VMODE = +1.8 V  
tꢂrougꢂ VEN pin  
0.04  
0.80  
BAꢀꢀ Current  
2.0  
tꢂrougꢂ VBAꢀꢀ, VMODE = +1.8 V  
VBAꢀꢀ = +4.4 V, VCC = +4.4 V,  
VEN = 0 V, VMODE = 0 V  
Leakage Current  
Noise Power  
-
6
15  
mA  
GPꢁ Band, 1573 - 1578 Mhz  
IꢁM Band, 2402 - 2480 Mhz  
RX Band, 2110 - 2170 Mhz  
POUꢀ < +28.2 dBm  
-
-
-
-138  
-136  
-137  
-
-
-
dBm/hz  
harmonics  
2fO  
3fO, 4fO  
-
-
-45  
-40  
-35  
-30  
dBc  
POUꢀ < +28.2 dBm  
Coupling Factor  
Directivity  
18.5  
-
20.5  
20  
22.5  
-
dB  
dB  
698 - 2620 Mhz  
Pin 15 tꢂrougꢂ 8, sꢂutdown mode  
Daisy Cꢂain Insertion Loss  
-
<0.30  
0.5  
-70  
-
dB  
POUꢀ < +28.2 dBm  
ꢁpurious Output Level  
(all spurious outputs)  
In-band load VꢁWR < 5:1  
Out-of-band load VꢁWR < 10:1  
Applies over all operating conditions  
-
-
-
dBc  
Load mismatcꢂ stress witꢂ no  
permanent degradation or failure  
8:1  
VꢁWR Applies over full operating range  
Notes:  
(1) ACLR and Efficiency measured at 1950 MHz.  
data sheet - Rꢀv 2.1  
01/2014  
4