AWT6321
ELECTRICAL CHARACTERISTICS
Table 2: Absolute Minimum and Maximum Ratings
PARAMETER
Supply Voltage (V
BATT
, V
CC
, V
CC
A)
Mode Control Voltage (V
MODE
)
Enable Voltage (V
EN_CELL
, V
EN_PCS
)
RF Input Power (P
IN
)
Storage Temperature (T
STG
)
MIN
0
0
0
-
-40
MAX
+5
+3.5
+3.5
+10
+150
UNIT
V
V
V
dBm
°C
Stresses in excess of the absolute ratings may cause permanent damage.
Functional operation is not implied under these conditions. Exposure
to absolute ratings for extended periods of time may adversely affect
reliability.
Table 3: Operating Ranges
PARAMETER
Operating Frequency (f)
Supply Voltage (V
CC
and V
BATT
)
Enable Voltage (V
EN
)
Mode Control Voltage (V
MODE
)
Cellular RF Output Power (P
OUT
)
CDMA
PCS RF Output Power (P
OUT
)
CDMA
Case Temperature (T
C
)
MIN
824
1850
+3.2
+2.2
0
+2.2
0
+27.5
+27.5
-30
(1)
TYP
-
+3.4
+2.4
-
+2.4
-
+28.0
+28.0
-
MAX
849
1915
+4.2
+3.1
+0.5
+3.1
+0.5
-
-
+85
UNIT
MHz
V
V
V
dBm
dBm
°C
COMMENTS
Cellular
PCS
PA "on"
PA "shut down"
Low Bias Mode
High Bias Mode
(1)
The device may be operated safely over these conditions; however, parametric performance is guaranteed only
over the conditions defined in the electrical specifications.
Notes:
(1) For operation at V
CC
= +3.2 V, P
OUT
is derated by 0.5 dB.
Data Sheet - Rev 2.2
10/2008
3