AWS5532R
Table 5: Electrical Specifications
(T
A
= +25
O
C, RF ports terminated with 50
Ω
, V
n
= +3.0 V and is the Control Voltage for the ON path, RFC-
RFn; V
X
= 0 V and is the Control Voltage for the other OFF path, RFC-RFx)
PARAMETER
Insertion Loss
1 GHz
2 GHz
Return Loss
1 GHz
2 GHz
Isolation
1 GHz
2 GHz
Input Third Order Intercept
(2)
824 - 849 MHz
Input Power for 0.1 dB
Compression
824 - 849 MHz
Current Consumption
(1)
MIN
-
-
-
-
27
25
+68
TYP
0.30
0.40
24
22
30
27
+71
MAX
0.5
0.6
20
18
-
-
-
UNIT
COMMENTS
dB
RFC port to selected RFn port
dB
RFC port and selected RFn port
dB
RFC port to isolated RFx port
dB m
RFC port to selected RFn port
+39
-
+40.5
-
-
50
dB m
mA
each Vn port
Notes:
(1) Isolated RFx ports have a return loss of approximately -3 dB.
(2) Two tones with PIN = +27 dBm each, 1 MHz channel spacing.
Table 6: Switch Control Truth Table
CONTROL VOLTAGE
V
1
+2.5 to +5 V
-0.2 to +0.2 V
V
2
-0.2 to +0.2 V
+2.5 to +5 V
RF PATH SELECTION
R FC - R F1
ON
OFF
R FC - R F2
OFF
ON
PRELIMINARY DATA SHEET - Rev 1.3
09/2005
5