AWL9966
ELECTRICAL CHARACTERISTICS
Table 2: Absolute Minimum and Maximum Ratings
Operating Conditions: TC=+25 °C, VCC=+3.3 V, Vcontrols=+3.3 V
PARAMETER
MIN
MAX UNIT
COMMENTS
DCꢀPowerꢀSupplyꢀVoltagesꢀ(VCC)
RFꢀInputꢀLevel,ꢀ2.4ꢀGHzꢀPA,ꢀ5ꢀGHzꢀPA
CaseꢀTemperature
-
+6.0
+5
V
dBm Modulated
-40
-55
-
+85
+85
60
C
C
StorageꢀTemperature
StorageꢀHumidity
%
C
ShippingꢀTemperature
ShippingꢀHumidity
-55
-
+150
60
%
ESDꢀTolerance
400
-
-
V
Humanꢀbodyꢀmodelꢀ(HBM),ꢀallꢀpins
MSLꢀRating
MSL-2
Notes:
1. Stresses in excess of the absolute ratings may cause permanent damage. Functional operation is not implied under
these conditions. Exposure to absolute ratings for extended periods of time may adversely affect reliability.
Table 3: Operating Ranges
PARAMETER
MIN
TYP
MAX
UNIT
MHz
V
COMMENTS
802.11b/g
2412
5150
2484
5850
OperatingꢀFrequencyꢀRanges
DCꢀPowerꢀSupplyꢀVoltageꢀ(VCC
802.11a
)
+3.0
+3.3
+4.2
WithꢀRFꢀapplied
ControlꢀPinꢀVoltageꢀ(PAON2,ꢀLNAON2,
PAON5,ꢀLNAON5,ꢀVBT2,ꢀVRX2,ꢀVTX2,
+2.8
0
+3.3
0
LogicꢀHigh/On
LogicꢀLow/Off
+
4.2
V
+0.5
V
RX5,ꢀVTX5)
8C
CaseꢀTemperature
-40
+85
NOTES:
The device may be operated safely over these conditions; however, parametric performance is guaranteed only over the
conditions defined in the electrical specifications.
PRELIMINARY DATA SHEET - Rev 1.0
3
07/2009