AWL9565
ELECTRICAL CHARACTERISTICS
Table 2: Absolute Minimum and Maximum Ratings
PARAMETER
DC Power Supply
RF Input Level, 5 GHz PA
Operating Ambient Temperature
Storage Temperature
Storage Humidity
Junction Temperature
ESD Tolerance
MSL Rating
MIN
-
-
-40
-55
-
-
400
-
MAX
+6.0
+5
+85
+85
60
150
-
MSL-2
UNIT
V
dBm
8C
8C
%
8C
V
Human body model (HBM)
Modulated
COMMENTS
Stresses in excess of the absolute ratings may cause permanent damage. Functional operation is not implied
under these conditions. Exposure to absolute ratings for extended periods of time may adversely affect
reliability.
Table 3: Operating Ranges
PARAMETER
Operating Frequency Ranges
DC Power Supply Voltage (V
CC
)
Control Pin Voltage (PA
ON
, Vbt, Vrx2,
Vtx2, Vrx5,Vtx5)
Operating Ambient Temperature
MIN
2412
5150
+2.8
+1.4
0
-40
TYP
-
-
+3.3
+1.8
0
-
MAX
2484
5850
+4.8
+V
CC
+0.5
+85
UNIT
MHz
V
V
8C
COMMENTS
802.11b/g/n
802.11a/n
With RF applied
Logic High/On
Logic Low/Off
The device may be operated safely over these conditions; however, parametric performance is guaranteed only
over the conditions defined in the electrical specifications.
Data Sheet - Rev 2.0
05/2011
3