AWL9232
Table 3: Operating Ranges
PARAMETER
Operating Frequency (f)
DC Power Supply Voltage (V
CC
)
Control Voltage (V
PA_EN
)
Control Voltage (V
BT_EN
)
Control Voltage (V
LNA_EN
)
Control Current (V
PA_EN
)
Control Current (V
BT_EN
)
Control Current (V
LNA_EN
)
Case Temperature (T
C
)
MIN
2400
+3.0
2.0
0
2.0
0
2.0
0
-
-
-
-
-
-
-40
TYP
-
+3.8
-
-
-
-
-
-
3
-
3
-
1
-
-
MAX
2500
+4.2
V
CC
+0.4
V
CC
+0.4
V
CC
+0.4
25
1
25
1
5
1
+85
UNIT
MHz
V
V
V
V
A
A
mA
A
°C
PA "ON"
PA "SHUTDOWN"
BT "ON"
BT "SHUTDOWN"
LNA "ON"
LNA "SHUTDOWN"
PA "ON"
PA "SHUTDOWN"
BT "ON"
BT "SHUTDOWN"
LNA "ON"
LNA "SHUTDOWN"
COMMENTS
The device may be operated safely over these conditions; however, parametric performance is guaranteed only
over the conditions defined in the electrical specifications.
4
PRELIMINARY DATA SHEET - Rev 1.0
04/2008