ARA2005
ELECTRICAL CHARACTERISTICS
Table 2: Absolute Minimum and Maximum Ratings
PAR AMETER
Analog Supply (pi ns 2, 4, 11, 20, 23)
Ampli fi er C ontrols Vg1, Vg2 (pi ns 7, 22)
RF
Power at Inputs
(pi ns 6
, 9
)
MIN
0
-5
-
0
-55
-
-
MAX
9
2
+60
6
+200
260
5
U N IT
VD C
V
dBmV
V
0
Attenuator C ontrols (pi ns 13, 14, 15, 16)
Storage Temperature
Solderi ng Temperature
Solderi ng Ti me
C
C
0
S ec
Stresses in excess of the absolute ratings may cause permanent damage.
Functional operation is not implied under these conditions. Exposure to
absolute ratings for extended periods of time may adversely affect
reliability.
Notes:
1. Pins 3, 6, 9, 12, 17, 18, 25 and 26 should be AC-coupled. No external DC
bias should be applied.
2. Pins 8 and 21 should be grounded or pulled to ground through a resistor. No
external DC bias should be applied.
Table 3: Operating Ranges
PAR AMETER
Ampli fi er Supply: V
DD
(pi ns 4, 11, 20, 23)
Attenuator Supply: V
ATTN
(pi n 2)
Attenuator C ontrols (pi ns 13, 14, 15, 16)
Ampli fi er C ontrols Vg1, Vg2 (pi ns 7, 22)
C ase Temperature
MIN
4.5
V
DD
-0.5
0
-5
-40
TYP
5
5
-
1
25
MAX
7
7
V
DD
+0.5
2
85
U N IT
VD C
VD C
V
V
0
C
The device may be operated safely over these conditions; however, parametric
performance is guaranteed only over the conditions defined in the electrical specifications.
4
PRELIMINARY DATA SHEET - Rev 1.3
08/2001