AGB3300
ELECTRICAL CHARACTERISTICS
Table 2: Absolute Minimum and Maximum Ratings
PARAMETER
MIN
MAX
+
UNIT
VDC
dBm
°C
Device Voltage
0
-
8
RF Input Power
+15
+150
+150
Storage Temperature
Channel Temperature
-40
-
°C
Stresses in excess of the absolute ratings may cause permanent
damage. Functional operation is not implied under these conditions.
Exposure to absolute ratings for extended periods of time may
adversely affect reliability.
Table 3: Operating Ranges
PARAMETER
MIN
250
-
TYP
MAX
3000
+6
UNIT
MHz
VDC
oC
Operating Frequency: f
Device Voltage: VDD
-
+5
-
Case Temperature: T
c
-40
+85
The device may be operated safely over these conditions; however,
parametric performance is guaranteed only over the conditions defined
in the electrical specifications.
Data Sheet - Rev 2.1
06/2003