ADA10000
ELECTRICAL CHARACTERISTICS
Table 3: Absolute Minimum and Maximum Ratings
PARAMETER
Supply
(S3 package: pin 14)
(S24 package: pin 3)
RF Power at Input
(S3 package: pin 6)
(S24 package: pin 1)
Storage Temperature
MIN
0
MAX
+12
UNIT
VD C
-
-65
+10
+150
dB m
°C
Stresses in excess of the absolute ratings may cause permanent
damage. Functional operation is not implied under these conditions.
Exposure to absolute ratings for extended periods of time may
adversely affect reliability.
Notes:
(1) RF input pin must be AC-coupled. No DC external bias should be
applied.
Table 4: Operating Ranges
PARAMETER
RF Input / Output Frequency
Supply Voltage (V
DD
)
Case Temperature
MIN
50
+4
-40
TYP
-
+8
-
MAX
1000
+9
+85
(1)
UNIT
MHz
VD C
°C
The device may be operated safely over these conditions; however, parametric
performance is guaranteed only over the conditions defined in the electrical
specifications.
Notes:
(1) Median time to failure will degrade above this temperature.
4
Data Sheet - Rev 2.3