ACA2601
ELECTRICAL CHARACTERISTICS
Table 2: Absolute Minimum and Maximum Ratings
PARAMETER
Supply Voltage (V
CC
)
AGC Voltage (V
AGC
)
RF Input Power (P
IN
)
Storage Temperature
MIN
0
0
-
-65
MAX
+8
+5
+25
+150
UNIT
V
V
dBmV
°C
Stresses in excess of the absolute ratings may cause permanent
damage. Functional operation is not implied under these conditions.
Exposure to absolute ratings for extended periods of time may
adversely affect reliability.
Table 3: Operating Ranges
PARAMETER
Operating Frequency (f)
Supply Voltage (V
CC
)
RF Output Power (P
OUT
)
Case Temperature (T
C
)
MIN
50
-
-
-40
TYP
-
+5
+18
-
MAX
870
-
-
+110
UNIT
MHz
V
dBmV
°C
COMMENTS
The device may be operated safely over these conditions; however, parametric performance is guaranteed
only over the conditions defined in the electrical specifications.
PRELIMINARY DATA SHEET - Rev 1.4
01/2006
3