AS1910 - AS1915
Data Sheet - Absolute Maximum Ratings
5 Absolute Maximum Ratings
Stresses beyond those listed in Table 3 may cause permanent damage to the device. These are stress ratings only,
and functional operation of the device at these or any other conditions beyond those indicated in Section 5 Electrical
Characteristics on page 3 is not implied. Exposure to absolute maximum rating conditions for extended periods may
affect device reliability.
Table 3. Absolute Maximum Ratings
Parameter
Min
-0.3
-0.3
Max Units
Comments
VCC, VCC2 to GND
Open-Drain RESETN
+5.0
+7.0
V
V
VCC +
0.3
Push/Pull RESET, RESETN
MRN, WDI, RESETIN to GND
-0.3
-0.3
V
V
VCC +
0.3
Input Current (VCC)
20
20
mA
mA
Output Current (RESET, RESETN)
Continuous Power Dissipation
(TAMB = +70ºC)
696
mW
Derate 8.7mW/ºC above +70ºC
Operating Temperature Range
Junction Temperature
-40
-65
+125
+150
+150
ºC
ºC
ºC
Storage Temperature Range
The reflow peak soldering temperature (body
temperature) specified is in accordance with
IPC/JEDEC J-STD-020C “Moisture/Reflow
Sensitivity Classification for Non-Hermetic Solid
State Surface Mount Devices”.
Package Body Temperature
+260
ºC
The lead finish for Pb-free leaded packages is
matte tin (100% Sn).
www.austriamicrosystems.com
Revision 1.00
3 - 15