 浏览型号AS1506-BTDT-50的Datasheet PDF文件第7页浏览型号AS1506-BTDT-50的Datasheet PDF文件第8页浏览型号AS1506-BTDT-50的Datasheet PDF文件第9页浏览型号AS1506-BTDT-50的Datasheet PDF文件第10页浏览型号AS1506-BTDT-50的Datasheet PDF文件第12页浏览型号AS1506-BTDT-50的Datasheet PDF文件第13页浏览型号AS1506-BTDT-50的Datasheet PDF文件第14页浏览型号AS1506-BTDT-50的Datasheet PDF文件第15页  
AS1506  
Datasheet - Detailed Description  
Copy Wiper Register to Non-Volatile Register  
This command can be implemented as an 8- or 16-bit command. The data stored in the wiper register are transferred  
to the non-volatile memory, to keep the data during power-down. There is no automatic trigger of this command during  
power-down of the device. This command must be triggered before powering down the device.  
There is a write non-volatile register time defined in the timing specification, which is required for storing the data in the  
non-volatile register. During this time the device must not be powered down, otherwise the data stored in the non-vola-  
tile register is corrupted.  
Copy Non-Volatile Register to Wiper Register  
This command can be implemented as an 8- or 16-bit command. The data stored in the non-volatile register are trans-  
ferred to the wiper register, the wiper register moves to the stored position. This command is automatically executed  
during power up of the system.  
Read Non-Volatile Register  
The AS1506 features the capability to read the data from the non-volatile register via the SPI interface (see Figure 23  
on page 12). This command can be implemented as an 8- or 16-bit command. The SDIO pin is a bi-directional pin.  
During the CSN low phase of the sequence the SDIO pin is used as input pin to set the command byte. After CSN ris-  
ing edge the pin SDIO is set as output pin, the data stored in the non-volatile register are read serially, MSB first.  
The data propagation starts at the second rising edge of SCLK after the rising edge of CSN. CSN must be high during  
the read operation. With the next falling edge of CSN the SDIO pin is set to an input pin again.  
Read Wiper Register  
The AS1506 features the capability to read the data from the wiper register via the SPI interface (see Figure 23 on  
page 12). This command can be implemented as an 8- or 16-bit command. The SDIO pin is a bi-directional pin. During  
the CSN low phase of the sequence, the SDIO pin is used as input pin to set the command byte. After CSN rising edge  
the pin SDIO is set as output pin, the data stored in the wiper register are read serially, MSB first. The wiper position is  
unchanged.  
The data propagation starts at the second rising edge of SCLK after the rising edge of CSN. CSN must be high during  
the read operation. With the next falling edge of CSN the SDIO pin is set to an input pin again.  
Figure 21. 8-Bit Command Word  
CSN  
SCLK  
SDIO  
C7  
C6  
C5  
C4  
C3  
C2  
C1  
C0  
www.austriamicrosystems.com  
Revision 1.02  