AS1326
Datasheet - E l e c t r i c a l C h a r a c t e r i s t i c s
Table 4. Electrical Characteristics (Continued)
Symbol
Logic Inputs
CLK/SEL Input Low Level
CLK/SEL Input High Level
ON, ONN Input Low Level
6
Parameter
Condition
Min
Typ
Max
Unit
2.5V
≤
V
OUT
≤
5.0V
2.5V
≤
V
OUT
≤
5.0V
1.1V
≤
V
OUT
≤
1.8V
1.8V
≤
V
OUT
≤
5.0V
6
0.2 x
V
OUT
0.8 x
V
OUT
0.2
0.4
V
OUT
-
0.2
1.6
0.1
200
100
1
V
V
V
1.1V
≤
V
OUT
≤
1.8V
1.8V
≤
V
OUT
≤
5.0V
CLK/SEL, ON, ONN, T
AMB
= +25ºC
ON, ONN Input High Level
Input Leakage Current
Minimum CLK/SEL
Pulse Width
Maximum CLK/SEL
Rise/Fall Time
V
µA
ns
ns
1. Operating voltage; since the regulator is bootstrapped to the output, once started, the AS1326 operates down to
0.7V input. If CLK/SEL = GND then V
IN
≤
V
OUT
. If CLK/SEL = V
OUT
then V
IN
≤
0.75xV
OUT
.
2. Startup is tested with the circuit shown in
3. Defines maximum step-up ratio.
4. The regulator is in startup mode until this voltage is reached.
Caution:
Do not apply full load current until the
device output > 2.3V.
5. Supply current into pin OUT. This current correlates directly to the actual battery-supply current, but is reduced
in value according to the step-up ratio and efficiency.
6. ON and ONN have a hysteresis of typically 0.15V.
www.austriamicrosystems.com
Revision 1.05
5 - 18