AS1112
Datasheet - Absolute Maximum Ratings
5 Absolute Maximum Ratings
Stresses beyond those listed in Table 3 may cause permanent damage to the device. These are stress ratings only,
and functional operation of the device at these or any other conditions beyond those indicated in Recommended Oper-
ating Conditions on page 4 is not implied. Exposure to absolute maximum rating conditions for extended periods may
affect device reliability.
Table 3. Absolute Maximum Ratings
Parameter
Min
Max
6
Units
V
Comments
Input Voltage Range to GND
Output Current (DC)
0.3
90
mA
VCC +
0.3
Input Voltage Range
-0.3
-0.3
-0.3
V
V
V
Output Voltage Range
VSDO, VXERR to GND
VCC +
0.3
Output Voltage Range
VOUT0: VOUT15 to GND
15
ESD Rating
2
kV
ºC
JEDEC 22-A114 Human Body Model
Storage Temperature Range
-55
-40
+150
Operating Ambient
Temperature Range
+85
23
ºC
32-pin TQFN 5x5 mm Package
Thermal Impedance
ºC/W
on 4-Layer PCB
The reflow peak soldering temperature (body
temperature) specified is in accordance with
IPC/JEDEC J-STD-020D “Moisture/Reflow
Sensitivity Classification for Non-Hermetic Solid
State Surface Mount Devices”.
Package Body Temperature
+260
ºC
The lead finish for Pb-free leaded packages is
matte tin (100% Sn).
www.austriamicrosystems.com
Revision 1.06
3 - 18