AS1106, AS1107
Data Sheet
- E l e c t r i c a l
Characteristics
Table 5. Timing Characteristics
Parameter
CLK Clock Period
CLK Pulse Width High
CLK Pulse Width Low
CSM Fall to CLK Rise Setup Time
(AS1107 or AS1106 SPI-programmed)
CLK Rise to LOAD/CSN Rise
Hold Time
DIN Setup Time
DIN Hold Time
Output Data Propagation Delay
LOAD Rising Edge to Next Clock Rising
Edge (AS1106 only)
Minimum LOAD/CSN Pulse High
Data-to-Segment Delay
Symbol
t
CP
t
CH
t
CL
t
CSS
t
CSH
t
DS
t
DH
t
DO
t
LDCK
t
CSW
t
DSPD
Conditions
Min
100
50
50
25
0
25
0
C
LOAD
= 50pF
50
50
2.25
25
Typ
Max
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ms
Note:
See Figure 12 on page 8 for more information.
www.austriamicrosystems.com
Revision 2.24