欢迎访问ic37.com |
会员登录 免费注册
发布采购

AMS2930 参数 Datasheet PDF下载

AMS2930图片预览
型号: AMS2930
PDF下载: 下载PDF文件 查看货源
内容描述: 该AMS2930系列由正面固定和可调电压稳压器非常适用于电池供电的系统中使用。 [The AMS2930 series consists of positive fixed and adjustable voltage regulators ideally suited for use in battery-powered systems.]
分类和应用: 稳压器电池
文件页数/大小: 9 页 / 253 K
品牌: AMS [ Advanced Monolithic Systems Ltd ]
 浏览型号AMS2930的Datasheet PDF文件第1页浏览型号AMS2930的Datasheet PDF文件第2页浏览型号AMS2930的Datasheet PDF文件第4页浏览型号AMS2930的Datasheet PDF文件第5页浏览型号AMS2930的Datasheet PDF文件第6页浏览型号AMS2930的Datasheet PDF文件第7页浏览型号AMS2930的Datasheet PDF文件第8页浏览型号AMS2930的Datasheet PDF文件第9页  
AMS2930  
Electrical Characteristics at VIN=14V, VOUT =3V IO =150mA, TJ=25°C, R1 =27k, C2 = 100µF unless otherwise specified.  
Electrical Characteristics  
AMS2930C  
PARAMETER  
CONDITIONS  
(Note 2)  
Units  
Min.  
Max.  
Typ.  
Adjustable Version  
Reference Voltage  
1.14  
1.20  
1.26  
V
V
IO 150 mA, -40°C T 125°C, R1=27k,  
J
1.08  
1.32  
Measured from VOUT to Adjust Pin  
Output Voltage Range  
Line Regulation  
3
24  
.02  
0.3  
V
mV  
%
1.5  
1
VOUT + 0.6V V 26V  
IN  
Load Regulation  
Dropout Voltage  
5mA I 150 mA  
O
I
10 mA  
0.05  
0.3  
0.2  
0.6  
V
V
O
I
= 150 mA  
O
Quiescent Current  
I
= 10 mA  
0.4  
15  
1
1
mA  
mA  
mA  
O
I
= 150 mA  
O
0.8  
During Shutdown RL = 500Ω  
10Hz-100kHz  
Output Noise Voltage  
Output Impedance  
Long Term Stability  
Ripple Rejection  
100  
40  
µVrms/V  
mΩ  
100mADC and 10mArms,100Hz=10kHz  
T =1000hr  
0.4  
0.02  
21  
%/1000hr  
%/V  
fO = 120Hz  
Maximum Operating Input  
Voltage  
22  
V
Maximum Line Transient  
60  
70  
V
IO = 10mA, Reference Voltage 1.5V  
T = 1ms, τ ≤100ms  
Reverse Polarity Input Voltage,  
D/C  
-15  
-50  
-30  
-80  
V
V
RL = 500, VO -0.3V  
RL = 500, T = 1ms, τ ≤100ms  
VO = 3V  
Reverse Polarity Input Voltage,  
Transient  
On/Off Threshold Voltage  
On  
2.0  
2.2  
20  
1.2  
50  
V
V
Off  
3.25  
On/Off Threshold Current  
µA  
Note 1: Absolute Maximum Ratings are limits beyond which damage to the device may occur. For guaranteed performance limits and associated test  
conditions, see the Electrical Characteristics tables.  
Note 2: See Circuit in Typical Applications. To ensure constant junction temperature, low duty cycle pulse testing is used.  
Note 3: Limits appearing in boldface type apply over the entire junction temperature range for operation. Limits appearing in normal type apply for  
TA = TJ = 25°C.  
Note 4: The junction-to-ambient thermal resistance are as follows: 195°C/W for the TO-92 (N) package, 160°C/W for the molded plastic SO-8 (S), 50°C/W  
for the TO-220 package and 73°C/W for the TO-263 package. If the TO-220 package is used with a heat sink, θJA is the sum of the package thermal resistance  
junction-to-case of 3°C/W and the thermal resistance added by the heat sink and the thermal interface. The thermal resistance of the TO-263 package can be  
reduced by increasing the PCB copper area thermally connected to the package: using 0.5 square inches of copper area, ϕ JA is 50°C/W; with 1 square inch of  
copper area ϕ JA is 37°C/W; and with 1.6 or more square inches of copper area ϕ JA is 32°C/W.  
3
Advanced Monolithic Systems http://www.ams-semitech.com