A29L040 Series  
I/O6: Toggle Bit I  
Reading Toggle Bits I/O6, I/O2  
Toggle Bit I on I/O6 indicates whether an Embedded Program  
or Erase algorithm is in progress or complete, or whether the  
device has entered the Erase Suspend mode. Toggle Bit I  
may be read at any address, and is valid after the rising edge  
Refer to Figure 4 for the following discussion. Whenever the  
system initially begins reading toggle bit status, it must read  
I/O7 - I/O0 at least twice in a row to determine whether a toggle  
bit is toggling. Typically, a system would note and store the  
value of the toggle bit after the first read. After the second  
read, the system would compare the new value of the toggle  
bit with the first. If the toggle bit is not toggling, the device has  
completed the program or erase operation. The system can  
read array data on I/O7 - I/O0 on the following read cycle.  
However, if after the initial two read cycles, the system  
determines that the toggle bit is still toggling, the system also  
should note whether the value of I/O5 is high (see the section  
on I/O5). If it is, the system should then determine again  
whether the toggle bit is toggling, since the toggle bit may have  
stopped toggling just as I/O5 went high. If the toggle bit is no  
longer toggling, the device has successfully completed the  
program or erase operation. If it is still toggling, the device did  
not complete the operation successfully, and the system must  
write the reset command to return to reading array data.  
The remaining scenario is that the system initially determines  
that the toggle bit is toggling and I/O5 has not gone high. The  
system may continue to monitor the toggle bit and I/O5 through  
successive read cycles, determining the status as described in  
the previous paragraph. Alternatively, it may choose to perform  
other system tasks. In this case, the system must start at the  
beginning of the algorithm when it returns to determine the  
status of the operation (top of Figure 4).  
of the final  
pulse in the command sequence (prior to the  
WE  
program or erase operation), and during the sector erase  
time-out.  
During an Embedded Program or Erase algorithm operation,  
successive read cycles to any address cause I/O6 to toggle.  
(The system may use either  
or  
to control the read  
CE  
OE  
cycles.) When the operation is complete, I/O6 stops toggling.  
After an erase command sequence is written, if all sectors  
selected for erasing are protected, I/O6 toggles for  
approximately 100μs, then returns to reading array data. If  
not all selected sectors are protected, the Embedded Erase  
algorithm erases the unprotected sectors, and ignores the  
selected sectors that are protected.  
The system can use I/O6 and I/O2 together to determine  
whether a sector is actively erasing or is erase-suspended.  
When the device is actively erasing (that is, the Embedded  
Erase algorithm is in progress), I/O6 toggles. When the  
device enters the Erase Suspend mode, I/O6 stops toggling.  
However, the system must also use I/O2 to determine which  
sectors are erasing or erase-suspended. Alternatively, the  
system can use I/O7 (see the subsection on " I/O7 :  
Data  
Polling").  
If a program address falls within a protected sector, I/O6  
toggles for approximately 2μs after the program command  
sequence is written, then returns to reading array data.  
I/O6 also toggles during the erase-suspend-program mode,  
and stops toggling once the Embedded Program algorithm is  
complete.  
The Write Operation Status table shows the outputs for  
Toggle Bit I on I/O6. Refer to Figure 4 for the toggle bit  
algorithm, and to the Toggle Bit Timings figure in the "AC  
Characteristics" section for the timing diagram. The I/O2 vs.  
I/O6 figure shows the differences between I/O2 and I/O6 in  
graphical form. See also the subsection on " I/O2: Toggle Bit  
II".  
I/O5: Exceeded Timing Limits  
I/O5 indicates whether the program or erase time has  
exceeded a specified internal pulse count limit. Under these  
conditions I/O5 produces a "1." This is a failure condition that  
indicates the program or erase cycle was not successfully  
completed.  
The I/O5 failure condition may appear if the system tries to  
program a "1 "to a location that is previously programmed to  
"0." Only an erase operation can change a "0" back to a "1."  
Under this condition, the device halts the operation, and when  
the operation has exceeded the timing limits, I/O5 produces a  
"1."  
Under both these conditions, the system must issue the reset  
command to return the device to reading array data.  
I/O2: Toggle Bit II  
The "Toggle Bit II" on I/O2, when used with I/O6, indicates  
whether a particular sector is actively erasing (that is, the  
Embedded Erase algorithm is in progress), or whether that  
sector is erase-suspended. Toggle Bit II is valid after the  
I/O3: Sector Erase Timer  
After writing a sector erase command sequence, the system  
may read I/O3 to determine whether or not an erase  
operation has begun. (The sector erase timer does not apply  
to the chip erase command.) If additional sectors are  
selected for erasure, the entire time-out also applies after  
each additional sector erase command. When the time-out is  
complete, I/O3 switches from "0" to "1." The system may  
ignore I/O3 if the system can guarantee that the time  
between additional sector erase commands will always be  
less than 50μs. See also the "Sector Erase Command  
Sequence" section.  
rising edge of the final  
pulse in the command sequence.  
WE  
I/O2 toggles when the system reads at addresses within those  
sectors that have been selected for erasure. (The system may  
use either  
or  
to control the read cycles.) But I/O2  
CE  
OE  
cannot distinguish whether the sector is actively erasing or is  
erase-suspended. I/O6, by comparison, indicates whether the  
device is actively erasing, or is in Erase Suspend, but cannot  
distinguish which sectors are selected for erasure. Thus, both  
status bits are required for sector and mode information. Refer  
to Table 5 to compare outputs for I/O2 and I/O6.  
After the sector erase command sequence is written, the  
Figure 4 shows the toggle bit algorithm in flowchart form, and  
the section " I/O2: Toggle Bit II" explains the algorithm. See  
also the " I/O6: Toggle Bit I" subsection. Refer to the Toggle Bit  
Timings figure for the toggle bit timing diagram. The I/O2 vs.  
I/O6 figure shows the differences between I/O2 and I/O6 in  
graphical form.  
system should read the status on I/O7 (  
Polling) or I/O6  
Data  
(Toggle Bit 1) to ensure the device has accepted the  
command sequence, and then read I/O3. If I/O3 is "1", the  
internally controlled erase cycle has begun; all further  
commands (other than Erase Suspend) are ignored until the  
(September, 2011, Version 1.6)  
12  
AMIC Technology, Corp.  
 复制成功!