A29002/A290021 Series
Timing Waveforms for Toggle Bit (During Embedded Algorithms)
tRC
Addresses
CE
VA
VA
VA
VA
tACC
tCE
tCH
tOE
OE
tDF
tOEH
WE
tOH
I/O6 , I/O2
Valid Status
(first read)
Valid Status
Valid Status
Valid Status
(second read)
(stop togging)
Note: VA = Valid Address; not required for I/O6. Illustration shows first two status cycle after command sequence, last status
read cycle, and array data read cycle.
(February, 2002, Version 1.0)