A276308A
AC Measurement Conditions
for 55 ns •Input Rise and Fall Times £ 10 ns
‚Input Pulse Voltage: 0V to 3Volt
ƒInput and Output Timing Ref. Voltage: 1.5Volt
3.0V
TEST
POINTS
1.5V
1.5V
0V
INPUT
OUTPUT
for 70/90 ns •Input Rise and Fall Times £ 10 ns
‚Input Pulse Voltage: 0.4V to 2.4Volt
ƒInput and Output Timing Ref. Voltage: 0.8V to 2.0Volt
2.4V
0.4V
2.0V
2.0V
0.8V
TEST
POINTS
0.8V
INPUT
OUTPUT
AC Testing Load Circuit
1.3V
1N914
3.3KW
DEVICE
UNDER
TEST
OUT
CL = 30pF or 100pF
CL = 30pF for 55 ns
CL = 100pF for 70/90 ns
CL includes JIG capacitance
(December, 2001, Version 1.0)
6
AMIC Technology, Inc.