A27020A Series
Programming and Program Verify
The programming flowchart is shown in Page 10.
The A27020A is shipped with all bits being set to "1".
Programming causes relevant bits to be changed to "0".
The programming mode is started by setting VCC to
+5.25V and VPP to +12.25V, while CE and PGM are
at V
IL
, and OE is at V
IH
. Data to be programmed can
be directly input in the 8 bit format through the data bus.
The write programming algorithm reduces programming
time by using 100
µ
s pulse followed by a byte
verification to determine whether the byte has been
successfully programmed. If the data does not pass the
verification, an additional pulse programming is applied
for a maximum of 25 pulses. On completion of 1 byte
programming and, The verified address is incremented.
After the final address is completed, all bytes are
verified again with VCC = 5.0 Volt.
Program Inhibit
This mode is used to program one of multiple A27020A
whose OE , PGM , VPP, VCC, address bus and data
bus are connected in parallel. When programming is
performed, other A27020A can be inhibited from being
programmed by setting their CE pins to V
IH
.
Programming Mode DC Characteristics
(Ta = 0
°
C to 70
°
C, VCC = 5.25V
±
0.25V, VPP = 12.25V
±
0.25V)
Symbol
V
OH
V
OL
V
IH
V
IL
I
LI
I
CC
I
PP
V
ID
VCC1
VPP1
Parameter
Output High Voltage
Output Low Voltage
Input High Voltage
Input Low Voltage
Input Leakage Current
VCC Current During Program
VPP Current During Program
A9 Auto Select Voltage
Programming Supply Voltage
Programming Voltage
11.5
5.0
12.0
2.0
-0.5
-1
Min.
2.4
0.4
VCC + 0.5
0.8
+1
50
50
12.5
5.5
12.5
Max.
Unit
V
V
V
V
µ
A
Test Conditions
I
OH
= -400
µ
A
I
OL
= 2.1mA
VCC = max. Vin = 0V to VCC
mA
mA
V
V
V
CE = V
IL
A9 = V
ID
Note: VCC must be applied simultaneously or before VPP and removed simultaneously or after VPP.
PRELIMINARY
(June, 2005, Version 0.1)
7
AMIC Technology, Corp.