 浏览型号AMIS-30623AANA的Datasheet PDF文件第42页浏览型号AMIS-30623AANA的Datasheet PDF文件第43页浏览型号AMIS-30623AANA的Datasheet PDF文件第44页浏览型号AMIS-30623AANA的Datasheet PDF文件第45页浏览型号AMIS-30623AANA的Datasheet PDF文件第47页浏览型号AMIS-30623AANA的Datasheet PDF文件第48页浏览型号AMIS-30623AANA的Datasheet PDF文件第49页浏览型号AMIS-30623AANA的Datasheet PDF文件第50页  
AMIS-30623 LIN Microstepping Motordriver  
Data Sheet  
16.6.4. Dynamic Assignment of Identifiers  
The identifier field in the LIN datagram denotes the content of the message. Six identifier bits and two parity bits are used to represent  
the content. The identifiers 0x3C and 0x3F are reserved for command frames and extended frames. Slave nodes need to be very  
flexible to adapt itself to a given LIN network in order to avoid conflicts with slave nodes from different manufacturers. Dynamic  
assignment of the identifiers will fulfill this requirement by writing identifiers into the circuits RAM. ROM pointers are linking commands  
and dynamic identifiers together. A writing frame with identifier 0x3C issued by the LIN master will write dynamic identifiers into the  
RAM. One writing frame is able to assign 4 identifiers, therefore 3 frames are needed to assign all identifiers. Each ROM pointer  
ROMp_x [3:0] place the corresponding dynamic identifier Dyn_ID_x [5:0] at the correct place in the RAM (see Table 1: LIN – Dynamic  
Identifiers Writing Frame).  
When setting <BROAD> to zero broadcasting is active and each slave on the LIN bus will store the same dynamic identifiers, otherwise  
only the slave with the corresponding slave address is programmed.  
Dynamic Identifiers Writing Frame  
Byte  
Content  
Structure  
Bit 4 Bit 3  
Bit 7  
Bit 6  
Bit 5  
Bit 2  
Bit 1  
Bit 0  
0
1
2
3
4
5
6
7
8
Identifier  
AppCmnd  
CMD  
Address  
Data  
Data  
Data  
Data  
Data  
0x3C  
0x80  
1
0x11  
AD3  
Broad  
AD6  
AD5  
AD4  
AD2  
AD1  
AD0  
DynID_1[3:0]  
DynID_2[1:0]  
ROMp_3[3:0]  
ROMp_4[2:0]  
ROMp_1[3:0]  
DynID_1[5:4]  
DynID_2[5:2]  
DynID_3[5:0]  
ROMp_2[3:0]  
DynID_4[5:0]  
ROMp_4[3:2]  
Where:  
CMD[6:0]:  
Broad:  
0x11, corresponding to dynamic assignment of four LIN identifiers  
If broad = ‘0’ all the circuits connected to the LIN bus will share the same dynamically assigned  
identifiers.  
DynID_x[5:0]: Dynamically assigned LIN identifier to the application command which ROM pointer is ROMp_x[3:0]  
One frame allows only to assign four identifiers. Therefore, additional frames could be needed in order to assign more identifiers  
(maximum three for the AMIS-30623).  
Dynamic ID  
ROM pointer  
Application Command  
User Defined  
0010  
GetActualPos  
User Defined  
User Defined  
User Defined  
User Defined  
User Defined  
User Defined  
User Defined  
User Defined  
User Defined  
0011  
0100  
0101  
0110  
0111  
0000  
0001  
1000  
1001  
GetStatus  
SetPosition  
SetPositionShort (1 m)  
SetPositionShort (2 m)  
SetPositionShort (4 m)  
GeneralPurpose 2 bytes  
GeneralPurpose 4bytes  
Preparation Frame  
SetPosParam  
Command assignement done at start-up  
Command assignement via Dynamic ID during operation  
Figure 26:Principle of Dynamic Command Assignment  
AMI Semiconductor – June 2006, Rev 3.0  
46  
www.amis.com