 浏览型号AMIS-30623AANA的Datasheet PDF文件第20页浏览型号AMIS-30623AANA的Datasheet PDF文件第21页浏览型号AMIS-30623AANA的Datasheet PDF文件第22页浏览型号AMIS-30623AANA的Datasheet PDF文件第23页浏览型号AMIS-30623AANA的Datasheet PDF文件第25页浏览型号AMIS-30623AANA的Datasheet PDF文件第26页浏览型号AMIS-30623AANA的Datasheet PDF文件第27页浏览型号AMIS-30623AANA的Datasheet PDF文件第28页  
AMIS-30623 LIN Microstepping Motordriver  
Data Sheet  
15.2.4. Sleep Mode  
When entering sleep mode, the stepper-motor can be driven to its secure position. After which, the circuit is completely powered down,  
apart from the LIN receiver, which remains active to detect dominant state on the bus. In case sleep mode is entered while a motion is  
ongoing, a transition will occur towards secure position as described in Positioning and Motion Control provided SecPos is enabled.  
Otherwise, SoftStopis performed.  
Sleep mode can be entered in the following cases:  
The circuit receives a LIN frame with identifier 0x3C and first data byte containing 0x00, as required by LIN specification  
rev 1.3. See Sleep  
In case the SleepEn bit =1 and the LIN bus remains inactive (or is lost) during more than 25000 time slots (1.30s at 19.2kbit/s),  
a time-out signal switches the circuit to sleep mode. See also  
The circuit will return to normal mode if a valid LIN frame is received while entering the sleep mode (this valid frame can be addressed  
to another slave).  
15.2.5. Thermal Shutdown Mode  
When thermal shutdown occurs, the circuit performs a SoftStopcommand and goes to Motor shutdown mode (see below).  
15.2.6. Temperature Management  
The AMIS-30623 monitors temperature by means of two thresholds and one shutdown level, as illustrated in the state diagram below.  
The only condition to reset flags <TW> and <TSD> (respectively thermal warning and thermal shutdown) is to be at a temperature lower  
than Ttw and to get the occurrence of a GetStatusor a GetFullStatusLIN frame.  
Normal Temp.  
Thermal warning  
Thermal shutdown  
T° > Ttw  
T° > Ttsd  
- <Tinfo> = “10”  
- <TW> = ‘1’  
- <TSD> = ‘0’  
- <Tinfo> = “00”  
- <TW> = ‘0’  
- <TSD> = ‘0’  
- <Tinfo> = “11”  
- <TW> = ‘1’  
- <TSD> = ‘1’  
- SoftStopif  
motion ongoing  
- Motor shutdown  
(motion disabled)  
T° < Ttw &  
LIN frame:  
GetStatusor  
GetFullStatus  
T° > Ttw  
T° < Ttw  
Post thermal  
warning  
T° > Ttsd  
T° < Ttsd  
- <Tinfo> = “00”  
- <TW> = ‘1’  
- <TSD> = ‘0’  
Post thermal  
shutdown 1  
T° < Tlow  
T° < Ttw  
- <Tinfo> = “10”  
- <TW> = ‘1’  
Post thermal  
shutdown 2  
T° > Tlow  
- <TSD> = ‘1’  
- Motor shutdown  
(motion disabled)  
- <Tinfo> = “00”  
- <TW> = ‘1’  
Low Temp.  
- <TSD> = ‘1’  
- Motor shutdown  
(motion disabled)  
- <Tinfo> = “01”  
- <TW> = ‘0’  
- <TSD> = ‘0’  
T° > Ttw  
Figure 16: State Diagram Temperature Management  
AMI Semiconductor – June 2006, Rev 3.0  
24  
www.amis.com  
 