 浏览型号AMIS-30623-AGA的Datasheet PDF文件第50页浏览型号AMIS-30623-AGA的Datasheet PDF文件第51页浏览型号AMIS-30623-AGA的Datasheet PDF文件第52页浏览型号AMIS-30623-AGA的Datasheet PDF文件第53页浏览型号AMIS-30623-AGA的Datasheet PDF文件第55页浏览型号AMIS-30623-AGA的Datasheet PDF文件第56页浏览型号AMIS-30623-AGA的Datasheet PDF文件第57页浏览型号AMIS-30623-AGA的Datasheet PDF文件第58页  
AMIS-30623 LIN Microstepping Motordriver  
Data Sheet  
GetOTPparam  
This command is provided to the circuit by the LIN master after a preparation frame (see Preparing frames) was issued, to read the  
content of an OTP memory segment which address was specified in the preparation frame.  
GetOTPparamcorresponds to a LIN in-frame response with 0x3D indirect ID.  
Preparing Frame  
Byte  
Content  
Structure  
Bit 7  
Bit 6  
*
Bit 5  
0
Bit 4  
ID4  
Bit 3  
ID3  
Bit 2  
ID2  
Bit 1  
ID1  
Bit 0  
ID0  
*
1
1
0
1
2
Identifier  
Data 1  
Data 2  
CMD[6:0] = 0x02  
AD[6:0]  
Reading Frame  
Byte  
Content  
Structure  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
0
1
1
1
1
1
0
1
0
1
2
3
4
5
6
7
Identifier  
Data 1  
Data 2  
Data 3  
Data 4  
Data 5  
Data 6  
Data 7  
Data 8  
OTP byte @0x00  
OTP byte @0x01  
OTP byte @0x02  
OTP byte @0x03  
OTP byte @0x04  
OTP byte @0x05  
OTP byte @0x06  
OTP byte @0x07  
8
Where:  
(*)  
According to parity computation  
GetStatus  
This command is provided to the circuit by the LIN master to get a quick status (compared to that of GetFullStatuscommand) of the  
circuit and of the stepper-motor. Refer to Flags Table to see the meaning of the parameters sent to the LIN master.  
Note: A GetStatus command will attempt to reset flags <TW>, <TSD>, <UV2>, <ElDef>, <StepLoss> and <VddReset>.  
GetStatuscorresponds to a 2 data bytes LIN in-frame response with a direct ID (type #5).  
GetStatus Reading Frame  
Byte  
Content  
Structure  
Bit 7  
*
ESW  
Bit 6  
*
Bit 5  
0
Bit 4 Bit 3 Bit 2  
Bit 1  
ID1  
Bit 0  
ID0  
ID4  
ID3  
AD[6:0]  
TSD  
ID2  
0
1
2
Identifier  
Data 1  
Data 2  
VddReset  
StepLoss  
ElDef  
UV2  
TW  
Tinfo[1:0]  
Where:  
(*)  
According to parity computation  
ID[5:0]:  