欢迎访问ic37.com |
会员登录 免费注册
发布采购

AMIS-30623-AGA 参数 Datasheet PDF下载

AMIS-30623-AGA图片预览
型号: AMIS-30623-AGA
PDF下载: 下载PDF文件 查看货源
内容描述: [Micro Peripheral IC,]
分类和应用:
文件页数/大小: 67 页 / 3352 K
品牌: AMI [ AMI SEMICONDUCTOR ]
 浏览型号AMIS-30623-AGA的Datasheet PDF文件第34页浏览型号AMIS-30623-AGA的Datasheet PDF文件第35页浏览型号AMIS-30623-AGA的Datasheet PDF文件第36页浏览型号AMIS-30623-AGA的Datasheet PDF文件第37页浏览型号AMIS-30623-AGA的Datasheet PDF文件第39页浏览型号AMIS-30623-AGA的Datasheet PDF文件第40页浏览型号AMIS-30623-AGA的Datasheet PDF文件第41页浏览型号AMIS-30623-AGA的Datasheet PDF文件第42页  
AMIS-30623 LIN Microstepping Motordriver  
Data Sheet  
15.3.8. Motor Shutdown Mode  
A motor shutdown occurs when:  
The chip temperature rises above the thermal shutdown threshold Ttsd (see Thermal Shutdown Mode)  
The battery voltage goes below UV2 (see Battery voltage management)  
Flag <ElDef> = ‘1’, meaning an electrical problem is detected on one or both coils, e.g. a short circuit.  
Flag <CPFail> = ‘1’, meaning there is a charge pump failure  
A motor shutdown leads to the following:  
H-bridges in high impedance mode  
The TagPosregister is loaded with the ActPos(to avoid any motion after leaving the motor shutdown mode)  
The LIN interface remains active, being able to receive orders or send status.  
The conditions to get out of a motor shutdown mode are:  
Reception of a GetStatusor GetFullStatuscommand AND  
The four above causes are no more detected  
Which leads to H-bridges in Ihold mode. Hence, the circuit is ready to execute any positioning command.  
This can be illustrated in the following sequence given as an application tip. The master can check whether there is a problem or not  
and decide which application strategy to adopt.  
Tj Tsd or  
Vbb UV2 or  
<ElDef> = ‘1’ or  
<CpFail> = ‘1’  
GetFullStatusor  
GetStatusframe  
GetFullStatusor  
GetStatusframe  
SetPosition  
frame  
…  
- The circuit is driven in - The position set-point - The application is  
- Possible confirmation  
motor shutdown  
mode  
is updated by the  
LIN Master  
aware of a problem  
of the problem  
- Reset <TW> or <TSD> or <UV2> or <StepLoss>  
or <ElDef> or <CPFail> by the application  
- The application is not - Motor shutdown  
aware of this  
mode no motion - Possible new detection of over temperature or  
- The application is still  
low voltage or electrical problem Circuit  
sets <TW> or <TSD> or <UV2> or  
<StepLoss> or <ElDef> or <CPFail>  
again at ‘1’  
unaware  
Figure 23:Example of Possible Sequence used to Detect and Determine Cause of Motor Shutdown  
Important: While in shutdown mode, since there is no hold current in the coils, the mechanical load can cause a step loss, which  
indeed cannot be flagged by the AMIS-30623.  
Warning: The application should limit the number of consecutive GetStatusor GetFullStatuscommands to try to get the AMIS-  
30623 out of shutdown mode when this proves to be unsuccessful, e.g. there is a permanent defect. The reliability of the circuit could  
be altered since Get(Full)Statusattempts to disable the protection of the H-bridges.  
Notes  
(0) The Priority Encoder is describing the management of states and commands. The note below is to be considered illustrative.  
(1) If the LIN communication is lost while in shutdown mode, the circuit enters the sleep mode immediately  
AMI Semiconductor – June 2006, Rev 3.0  
38  
www.amis.com