AME
AME1300
n
Electrical Specifications(contd.)
RESET Output
Parameter
V
DET
Range
Symbol
V
DET
Test Condition
T
A
= -40 to +85
o
C
T
A
= 25
o
C
Reset Threshold
V
TH
T
A
= -40 to +85 C
RESET Threshold Tempco
RESETB Output Voltage Low
RESETB Output Voltage High
V
DET
to Reset Delay
Reset Active Timeout Period*
V
OL
V
OH
T
D1
T
D2
V
DET
<V
TH
min
V
DET
>V
TH
max
I
SINK
=1.2mA,
T
A
= -40 to +85
o
C
I
SOURCE
=0.5mA,
T
A
= -40 to +85
o
C
o
300mA CMOS LDO with
RESET Function
Min
1
2.59
2.58
Typ
Max
5.5
Units
V
2.63
2.67
V
2.68
30
0.5
0.8V
DET
40
140
210
500
ppm
V
V
µS
mS
V
DET
= V
TH
- 100mV, T
A
= -40 to +85
o
C
T
A
= -40 ~ +85
o
C
n
Timing Diagram
V
Release
V
T H
V
IN
T
D2
50%
RESET
T
D1
50%
T
D2
50%
RESETB
T
D1
50%
6
Rev.C.02