ABSOLUTE MAXIMUM RATINGS
Storage Temperature
Plastic Packages . . . . . . . . . . . . . . . –65°C to +125°C
20 ns
20 ns
Ambient Temperature
with Power Applied. . . . . . . . . . . . . . –55°C to +125°C
+0.8 V
Voltage with Respect to Ground
–0.5 V
–2.0 V
VCC (Note 1) . . . . . . . . . . . . . . . . .–2.0 V to 7.0 V
A9, OE# (Note 2). . . . . . . . . . . . .–2.0 V to 12.5 V
All other pins (Note 1) . . . . . . . . . .–2.0 V to 7.0 V
Output Short Circuit Current (Note 3) . . . . . . 200 mA
20 ns
Figure 5. Maximum Negative
Overshoot Waveform
Notes:
1. Minimum DC voltage on input or I/O pins is –0.5 V. During
voltage transitions, inputs may undershoot V to –2.0 V
SS
for periods of up to 20 ns. See Figure 5. Maximum DC
voltage on input and I/O pins is V
+ 0.5 V. During
CC
voltage transitions, input and I/O pins may overshoot to
+ 2.0 V for periods up to 20 ns. See Figure 6.
20 ns
V
CC
2. Minimum DC input voltage on A9 pin is –0.5 V. During
V
CC
voltage transitions, A9 and OE# may undershoot V to
+2.0 V
SS
–2.0 V for periods of up to 20 ns. See Figure 5. Maximum
DC input voltage on A9 and OE# is 12.5 V which may
overshoot to 13.5 V for periods up to 20 ns.
V
CC
+0.5 V
2.0 V
3. No more than one output shorted to ground at a time.
Duration of the short circuit should not be greater than
one second.
20 ns
20 ns
Figure 6. Maximum Positive
Overshoot Waveform
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device. This is
a stress rating only; functional operation of the device at
these or any other conditions above those indicated in the op-
erational sections of this specification is not implied. Expo-
sure of the device to absolute maximum rating conditions for
extended periods may affect device reliability.
OPERATING RANGES
Commercial (C) Devices
Ambient Temperature (TA) . . . . . . . . . . . 0°C to +70°C
Industrial (I) Devices
Ambient Temperature (TA) . . . . . . . . . –40°C to +85°C
Extended (E) Devices
Ambient Temperature (TA) . . . . . . . . –55°C to +125°C
V
Supply Voltages
CC
VCC for ± 5% devices. . . . . . . . . . .+4.75 V to +5.25 V
VCC for ± 10% devices. . . . . . . . . . . .+4.5 V to +5.5 V
Operating ranges define those limits between which the
functionality of the device is guaranteed.
Am29F040B